Literature DB >> 20553569

Using 20-gauge percutaneous peripheral catheters to reliably collect serial 4-mL blood samples from conscious dogs.

K F Elliott1, L M Fleeman, J S Rand.   

Abstract

OBJECTIVE: To determine the reliability of collecting serial 4-mL blood samples over 13 h using a 20-gauge, cephalic catheter in conscious dogs.
DESIGN: Prospective, observational study. ANIMALS: Twelve (6 males, 6 females) healthy, neutered, lean dogs. PROCEDURE: Percutaneous placement of a 20-gauge, 1.1 x 30 mm intravenous over-the-needle catheter into the cephalic vein was performed in each dog on three occasions. Catheter patency was maintained by intermittent flushing with 0.9% saline and 1 IU/mL heparinised saline solutions. Blood samples (4 mL) were obtained at 10 time-points over 13 h, with close monitoring of the dogs and the indwelling catheters. Blood volume, resistance on aspirating blood sample (minimal or marked resistance) and the methods used to improve blood flow were recorded.
RESULTS: A high proportion (93%) of blood sample collections achieved the required 4-mL volume, and the remaining samples were greater than 1.5 mL. Of the 358 collections via the cephalic catheter, 311 (87%) were obtained with 'minimal resistance'. The remaining collections had 'marked resistance' (n=47) and were associated with a loose catheter in 11% (5/47) and of unknown cause in 89% (42/47). After 'marked resistance' had been encountered and the catheter was flushed with saline and heparin solutions, subsequent sampling with 'minimal resistance' was frequently possible from the same catheter.
CONCLUSION: Use of a percutaneous, 20-gauge intravenous cephalic catheter allowed reliable serial collection of 4-mL blood samples over 13 h in conscious dogs.

Entities:  

Mesh:

Year:  2010        PMID: 20553569     DOI: 10.1111/j.1751-0813.2010.00580.x

Source DB:  PubMed          Journal:  Aust Vet J        ISSN: 0005-0423            Impact factor:   1.281


  3 in total

1.  Comparison of heparinized saline and 0.9% sodium chloride for maintaining central venous catheter patency in healthy dogs.

Authors:  Julieann Vose; Adesola Odunayo; Joshua M Price; Maggie Daves; Julie C Schildt; M Katherine Tolbert
Journal:  PeerJ       Date:  2019-05-31       Impact factor: 2.984

2.  Comparison of Hematological and Biochemical Results Derived from Arterial and Venous Blood Samples in Post-Anesthetic Dogs.

Authors:  Song Mi Lee; Byung-Jae Kang; Sungin Lee; Wan Hee Kim
Journal:  Animals (Basel)       Date:  2020-11-09       Impact factor: 2.752

3.  Comparison of biochemical and hematologic values obtained via jugular venipuncture and peripheral intravenous catheters in dogs.

Authors:  Aria L Guarino; Andrew J Specht; Sarah S K Beatty; Allison L O'Kell
Journal:  J Vet Intern Med       Date:  2022-08-27       Impact factor: 3.175

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.