Literature DB >> 20552382

Metal ion-mobilizing additives for comprehensive detection of femtomole amounts of phosphopeptides by reversed phase LC-MS.

Joerg Seidler1, Nico Zinn, Erik Haaf, Martin E Boehm, Dominic Winter, Andreas Schlosser, Wolf D Lehmann.   

Abstract

It is hypothesized that metal ion-mediated adsorption of phosphorylated peptides on stationary phases of LC-columns is the major cause for their frequently observed poor detection efficiency in LC-MS. To study this phenomenon in more detail, sample solutions spiked with metal ion-mobilizing additives were analyzed by reversed phase μLC-ICP-MS or nanoLC-ESI-MS. Using μLC-ICP-MS, metal ions were analyzed directly as atomic ions. Using electrospray ionization, either metal ion chelates or phosphopeptide standard mixtures injected in subpicomole amounts were analyzed. Deferoxamine, imidazole, ascorbate, citrate, EDTA, and the tetrapeptide pSpSpSpS were tested as sample additives for the interlinked purposes of metal ion-mobilization and improvement of phosphopeptide recovery. Iron probably represents the major metal ion contamination of reversed phase columns. Based on the certified iron level in LC-grade solvents, a daily metal ion load of >10 pmol was estimated for typical nanoLC flow rates. In addition, phosphopeptide fractions from IMAC columns were identified as source for metal ion contamination of the LC column, as demonstrated for Ga(3+)-IMAC. The three metal ion-chelating additives, EDTA, citrate and pSpSpSpS, were found to perform best for improving the LC recovery of multiply phosphorylated peptides injected at subpicomole amounts. The benefits of metal ion-mobilizing LC (mimLC) characterized by metal ion complexing sample additives is demonstrated for three different instrumental setups comprising (a) a nanoUPLC-system with direct injection on the analytical column, (b) a nanoLC system with inclusion of a trapping column, and (c) the use of a HPLC-Chip system with integrated trapping and analytical column.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20552382     DOI: 10.1007/s00726-010-0647-7

Source DB:  PubMed          Journal:  Amino Acids        ISSN: 0939-4451            Impact factor:   3.520


  2 in total

1.  Comprehensive and reproducible phosphopeptide enrichment using iron immobilized metal ion affinity chromatography (Fe-IMAC) columns.

Authors:  Benjamin Ruprecht; Heiner Koch; Guillaume Medard; Max Mundt; Bernhard Kuster; Simone Lemeer
Journal:  Mol Cell Proteomics       Date:  2014-11-13       Impact factor: 5.911

2.  Division of labor by dual feedback regulators controls JAK2/STAT5 signaling over broad ligand range.

Authors:  Julie Bachmann; Andreas Raue; Marcel Schilling; Martin E Böhm; Clemens Kreutz; Daniel Kaschek; Hauke Busch; Norbert Gretz; Wolf D Lehmann; Jens Timmer; Ursula Klingmüller
Journal:  Mol Syst Biol       Date:  2011-07-19       Impact factor: 11.429

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.