Literature DB >> 20552305

In vivo and in vitro analysis of rat lumbar spine mechanics.

Matthew E Cunningham1, Jocelyn M Beach, Serkan Bilgic, Oheneba Boachie-Adjei, Marjolein C H van der Meulen, Chisa Hidaka.   

Abstract

BACKGROUND: Rodent lumbar and caudal (tail) spine segments provide useful in vivo and in vitro models for human disc research. In vivo caudal models allow characterization of the effect of static and dynamic loads on disc mechanics of individual animals with time, but the lumbar models have required sacrifice of the animals for in vitro mechanical testing. QUESTIONS/PURPOSES: We therefore developed a novel displacement controlled in vivo lumbar spine noninvasive induced angular displacement (NIAD) test; data obtained with NIAD were used to compare angular displacement between segmental levels (L4/L5, L5/L6 and L6/S1), interobserver radiograph measurement agreement, and intraobserver radiograph measurement repeatability. Measurements from NIAD were compared with angular displacement, bending stiffness, and moment to failure measured by an in vitro test.
METHODS: Anesthetized Lewis rats were xrayed in a 90° angled fixture, and NIAD was measured at lumbar levels L4 to S1 by two independent and blinded observers. After euthanasia, in vitro angular displacement (IVAD), stiffness, and failure moment were measured for the combined L4-L6 segment in four-point bending.
RESULTS: NIAD was greater at L4/L5 and L5/L6 than at L6/S1. Combined coronal NIAD for L4-L6 was 42.8° ± 5.3° and for IVAD was 61.5° ± 3.8°. Reliability assessed by intraclass correlation coefficient (ICC) was 0.905 and 0.937 for intraobserver radiograph measurements, and interobserver ICCs ranged from 0.387 to 0.653 for individual levels. The interobserver ICC was 0.911 for combined data from all levels. Reliability for test-retest NIAD measurements had an ICC of 0.932. In vitro failure moment correlated with NIAD left bending.
CONCLUSIONS: The NIAD method yielded reproducible and reliable rat lumbar spine angular displacement measurements without required euthanasia, and allows repetitive monitoring of animals with time. For lumbar spine research studies performed during a course of time, the NIAD method may reduce animal numbers required by providing serial angular displacement measurements without euthanasia. CLINICAL RELEVANCE: Improved methods to assess comparative models for disease or aging may permit enhanced clinical treatments and improved patient care.

Entities:  

Mesh:

Year:  2010        PMID: 20552305      PMCID: PMC3049628          DOI: 10.1007/s11999-010-1421-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  42 in total

1.  Intervertebral disc changes in an animal model representing altered mechanics in scoliosis.

Authors:  I A F Stokes; C A McBride; D D Aronsson
Journal:  Stud Health Technol Inform       Date:  2008

2.  Rotational changes of the vertebral-pelvic axis following Cotrel-Dubousset instrumentation.

Authors:  K B Wood; E E Transfeldt; J W Ogilvie; M J Schendel; D S Bradford
Journal:  Spine (Phila Pa 1976)       Date:  1991-08       Impact factor: 3.468

3.  Comparison of animal discs used in disc research to human lumbar disc: axial compression mechanics and glycosaminoglycan content.

Authors:  Jesse C Beckstein; Sounok Sen; Thomas P Schaer; Edward J Vresilovic; Dawn M Elliott
Journal:  Spine (Phila Pa 1976)       Date:  2008-03-15       Impact factor: 3.468

4.  Reduced nucleus pulposus glycosaminoglycan content alters intervertebral disc dynamic viscoelastic mechanics.

Authors:  John I Boxberger; Amy S Orlansky; Sounok Sen; Dawn M Elliott
Journal:  J Biomech       Date:  2009-06-18       Impact factor: 2.712

5.  Osteoinductivity of commercially available demineralized bone matrix. Preparations in a spine fusion model.

Authors:  Brett Peterson; Peter G Whang; Roberto Iglesias; Jeff C Wang; Jay R Lieberman
Journal:  J Bone Joint Surg Am       Date:  2004-10       Impact factor: 5.284

6.  Rat disc torsional mechanics: effect of lumbar and caudal levels and axial compression load.

Authors:  Alejandro A Espinoza Orías; Neil R Malhotra; Dawn M Elliott
Journal:  Spine J       Date:  2008-05-20       Impact factor: 4.166

7.  An in vivo model of reduced nucleus pulposus glycosaminoglycan content in the rat lumbar intervertebral disc.

Authors:  John I Boxberger; Joshua D Auerbach; Sounok Sen; Dawn M Elliott
Journal:  Spine (Phila Pa 1976)       Date:  2008-01-15       Impact factor: 3.468

Review 8.  Are animal models useful for studying human disc disorders/degeneration?

Authors:  Mauro Alini; Stephen M Eisenstein; Keita Ito; Christopher Little; A Annette Kettler; Koichi Masuda; James Melrose; Jim Ralphs; Ian Stokes; Hans Joachim Wilke
Journal:  Eur Spine J       Date:  2007-07-14       Impact factor: 3.134

9.  Existence of nerve growth factor receptors, tyrosine kinase a and p75 neurotrophin receptors in intervertebral discs and on dorsal root ganglion neurons innervating intervertebral discs in rats.

Authors:  Ai Sugiura; Seiji Ohtori; Masaomi Yamashita; Gen Inoue; Kazuyo Yamauchi; Takana Koshi; Munetaka Suzuki; Masaki Norimoto; Sumihisa Orita; Yawara Eguchi; Yuzuru Takahashi; Tomoko Saito Watanabe; Nobuyasu Ochiai; Masashi Takaso; Kazuhisa Takahashi
Journal:  Spine (Phila Pa 1976)       Date:  2008-09-01       Impact factor: 3.468

10.  Evaluation of conservative treatment of non specific spondylodiscitis.

Authors:  N Bettini; M Girardo; E Dema; S Cervellati
Journal:  Eur Spine J       Date:  2009-05-05       Impact factor: 3.134

View more
  4 in total

1.  Micro-computed tomography-based three-dimensional kinematic analysis during lateral bending for spinal fusion assessment in a rat posterolateral lumbar fusion model.

Authors:  Tomonori Yamaguchi; Nozomu Inoue; Robert L Sah; Yu-Po Lee; Alexander P Taborek; Gregory M Williams; Timothy A Moseley; Won C Bae; Koichi Masuda
Journal:  Tissue Eng Part C Methods       Date:  2014-01-09       Impact factor: 3.056

2.  Flexible active electrode arrays with ASICs that fit inside the rat's spinal canal.

Authors:  Vasiliki Giagka; Andreas Demosthenous; Nick Donaldson
Journal:  Biomed Microdevices       Date:  2015-12       Impact factor: 2.838

3.  Lumbar spine intervertebral disc gene delivery of BMPs induces anterior spine fusion in lewis rats.

Authors:  Matthew E Cunningham; Natalie H Kelly; Bernard A Rawlins; Oheneba Boachie-Adjei; Marjolein C H van der Meulen; Chisa Hidaka
Journal:  Sci Rep       Date:  2022-10-07       Impact factor: 4.996

4.  Assessment of a rabbit posterolateral spinal fusion using movement between vertebrae: a modification of the palpation exam for quantifying fusions.

Authors:  Sohrab S Virk; Alex Aurand; Alicia L Bertone; Hayam Hussein; Mari Kaido; William S Marras; Safdar N Khan
Journal:  J Spine Surg       Date:  2019-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.