Deep sclerectomy with the Ex-PRESS X-200 implant for the surgical treatment of glaucoma.

Alexandre Bissig1, Michael Feusier, André Mermoud, Sylvain Roy.   

Abstract

The efficacy and safety of a newly designed Ex-PRESS X-200 drainage device for the surgical treatment of glaucoma was evaluated. A clinical, prospective, monocentric, non-randomised, unmasked study on patients with medically uncontrolled glaucoma was performed. A superficial scleral flap was created. A posterior deep sclerectomy (DS) was dissected without opening the Schlemm's canal and an Ex-PRESS X-200 device was inserted under the scleral flap into the anterior chamber to drain aqueous humour into the intrascleral space. Biomicroscopy, best-corrected visual acuity (BCVA), applanation intra-ocular pressure (IOP) measurements, and fundus examination were performed before surgery, on the first day, the first week, and 1, 2, 3, 6, 12 and 18 months after surgery. The mean follow-up was 18.6 ± 2.4 months (mean ± SD) for the 26 eyes that were treated with the Ex-PRESS X-200 device. Pre-operatively, the mean BCVA was 0.6 ± 0.3, the mean IOP was 22.0 ± 5.1 mmHg, and the mean number of medications per patients was 2.8 ± 0.8. Eighteen months after surgery the mean BCVA was 0.5 ± 0.4, the mean IOP was reduced to 12.0 ± 3.9 mmHg, and the mean number of medications per patient was 0.6 ± 1.2. Eighty-five percent of patients achieved an IOP < 18 mmHg with or without medication and 69% without medication. Post-operative complications were hyphaema (15%), Seidel (15%), encysted blebs (54%) and bleb fibrosis in 8% of patients. Mitomycin C(MMC) was administered to 15 patients (58%) with needling being performed on 10 (38%) of these patients. Mid-term results of DS with the Ex-PRESS X-200 implant demonstrated its efficacy in controlling IOP with few post-operative complications in difficult eyes with an increased risk of surgery failure.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20552258     DOI: 10.1007/s10792-010-9382-z

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  24 in total

1.  Surgery for glaucoma in the 21st century.

Authors:  P T Khaw; A P Wells; K S Lim
Journal:  Br J Ophthalmol       Date:  2002-07       Impact factor: 4.638

2.  Ex-PRESS implant.

Authors:  A Mermoud
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

3.  Long-term post trabeculectomy intraocular pressures.

Authors:  S K Akafo; D B Goulstine; A R Rosenthal
Journal:  Acta Ophthalmol (Copenh)       Date:  1992-06

4.  Spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS).

Authors:  M Tavolato; S Babighian; A Galan
Journal:  Eur J Ophthalmol       Date:  2006 Sep-Oct       Impact factor: 2.597

5.  Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap.

Authors:  Peter J G Maris; Kyoko Ishida; Peter A Netland
Journal:  J Glaucoma       Date:  2007-01       Impact factor: 2.503

6.  Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification.

Authors:  C E Traverso; F De Feo; A Messas-Kaplan; P Denis; S Levartovsky; E Sellem; F Badalà; Z Zagorski; A Bron; S Gandolfi; M Belkin
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

7.  The complications of trabeculectomy (a 20-year follow-up).

Authors:  P G Watson; C Jakeman; M Ozturk; M F Barnett; F Barnett; K T Khaw
Journal:  Eye (Lond)       Date:  1990       Impact factor: 3.775

8.  Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study.

Authors:  Sonja Wamsley; Marlene R Moster; Sushma Rai; Heryberto S Alvim; Joann Fontanarosa
Journal:  Am J Ophthalmol       Date:  2004-12       Impact factor: 5.258

9.  Deep sclerectomy with collagen implant in one eye compared with trabeculectomy in the other eye of the same patient.

Authors:  Aude Ambresin; Tarek Shaarawy; Andre Mermoud
Journal:  J Glaucoma       Date:  2002-06       Impact factor: 2.503

10.  Long-term survival of Molteno glaucoma drainage devices.

Authors:  R P Mills; A Reynolds; M J Emond; W E Barlow; M M Leen
Journal:  Ophthalmology       Date:  1996-02       Impact factor: 12.079

View more
  8 in total

1.  IOP-lowering effects for the application of human umbilical vein in non-penetrating deep sclerostomy in rabbits.

Authors:  Yang Yang; Yu Di; Dong-Mei Gui; Zhi-Li Liu; Xin Liu; Dian-Wen Gao
Journal:  Int J Ophthalmol       Date:  2011-02-18       Impact factor: 1.779

2.  Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma.

Authors:  Kyoko Ishida; Naoya Moroto; Kazuhiro Murata; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2017-04-03       Impact factor: 2.447

3.  Modified deep sclerectomy combined with Ex-PRESS filtration device versus trabeculectomy for primary open angle glaucoma.

Authors:  Vassilios Kozobolis; Georgios D Panos; Aristeidis Konstantinidis; Miguel Teus; Georgios Labiris
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

4.  Efficacy and Safety of the Preserflo Microshunt With Mitomycin C for the Treatment of Open Angle Glaucoma.

Authors:  Marta Ibarz Barberá; Fátima Martínez-Galdón; Elena Caballero-Magro; Marta Rodríguez-Piñero; Pedro Tañá-Rivero
Journal:  J Glaucoma       Date:  2022-05-17       Impact factor: 2.290

Review 5.  Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device.

Authors:  C Mariotti; E Dahan; M Nicolai; L Levitz; S Bouee
Journal:  Eye (Lond)       Date:  2013-11-15       Impact factor: 3.775

6.  ExPress mini shunt device with trabeculectomy surgery in patients with uncontrolled glaucoma of Middle Eastern descent.

Authors:  Mohammad A AlSemari; Adi M Al Owaifeer; Faisal AlMubarak; Abdulsalam Turjoman; Essam A Osman
Journal:  Saudi J Ophthalmol       Date:  2021-02-27

7.  Surgical treatment of neovascular glaucoma with Ex-PRESS glaucoma shunt: Case report.

Authors:  Teng-Chieh Yu; Gow-Lieng Tseng; Chun-Chen Chen; Shiow-Wen Liou
Journal:  Medicine (Baltimore)       Date:  2017-09       Impact factor: 1.889

8.  Comparison of ExPress Implantation and Partial Deep Sclerectomy Combined with ExPress Implantation and Simultaneous Phacoemulsification.

Authors:  Marietta Frączkiewicz-Skok; Joanna Konopińska; Zofia Mariak; Marek Rękas
Journal:  J Ophthalmol       Date:  2019-11-28       Impact factor: 1.909

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.