Benefits of continuous glucose monitor use in clinical practice.

Matthew Leinung1, Shannon Thompson, Elizabeth Nardacci.   

Abstract

OBJECTIVE: To determine the benefits of personal continuous glucose monitoring (CGM) outside of a controlled clinical trial in a single ambulatory diabetes clinic.
METHODS: In this retrospective study, we reviewed medical records of all patients who began CGM in our university-based clinical practice between July 2006 and October 2008. Data pertaining to 1 year before initiation of CGM through January 2009 were collected. All patient visits were performed by any 1 of 7 board-certified endocrinologists and/or 5 certified diabetes educators. A severe hypoglycemic event was considered to have occurred if the patient reported requiring assistance or losing consciousness, or if there was documentation from another source (eg, an emergency department visit). Analysis of the effect of CGM on hemoglobin A1c and occurrence of severe hypoglycemia was performed.
RESULTS: A total of 117 patients initiated CGM between July 2006 and October 2008 and used CGM for at least 2 months (total experience on CGM, 1136 patient-months; average 9.7 months per patient). Mean age was 44.5 +/- 12.8 years (range, 14.3-71.7 years), and average duration of diabetes mellitus was 23.9 years. All patients were using insulin pumps before initiation of CGM, including 10 patients with type 2 diabetes. Sixty-eight patients (58%) had preexisting hypoglycemia unawareness. Average hemoglobin A1c level for 1 year before CGM initiation was 7.6 +/- 1.1%, and with CGM use it dropped to 7.2 +/- 0.8% (P<.001). Forty-two patients had severe hypoglycemic events in the year before CGM use or during CGM use. Overall, CGM use was associated with a significant decrease in the rate of severe hypoglycemic episodes (odds ratio, 0.40; 95% confidence interval, 0.24-0.65).
CONCLUSIONS: Personal CGM, in a real-world setting, improves glucose control and reduces the rate of severe hypoglycemic episodes.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20551007     DOI: 10.4158/EP09287.OR

Source DB:  PubMed          Journal:  Endocr Pract        ISSN: 1530-891X            Impact factor:   3.443


  10 in total

1.  GlyCulator: a glycemic variability calculation tool for continuous glucose monitoring data.

Authors:  Dorota Czerwoniuk; Wojciech Fendler; Lukasz Walenciak; Wojciech Mlynarski
Journal:  J Diabetes Sci Technol       Date:  2011-03-01

2.  Intraindividual differences between two simultaneous glucose measurement systems in type 2 diabetic patients.

Authors:  Lars Stechemesser; Agnes Hammerschmied; Brigitta Gappmayer; Mynda Schreuer; Raimund Weitgasser
Journal:  Wien Klin Wochenschr       Date:  2012-07-06       Impact factor: 1.704

Review 3.  Technology to Reduce Hypoglycemia.

Authors:  Ester Yeoh; Pratik Choudhary
Journal:  J Diabetes Sci Technol       Date:  2015-04-16

4.  Effect on glycemic control by short- and long-term use of continuous glucose monitoring in clinical practice.

Authors:  Jenny Anderson; Stig Attvall; Lennart Sternemalm; Aldina Pivodic; Martin Fahlén; Ragnar Hanås; Gunnar Ekeroth; Marcus Lind
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

5.  Exercise-related hypoglycemia in diabetes mellitus.

Authors:  Lisa M Younk; Maia Mikeladze; Donna Tate; Stephen N Davis
Journal:  Expert Rev Endocrinol Metab       Date:  2011-01-01

6.  Continuous Glucose Monitoring for the Detection of Hypoglycemia in Patients With Diabetes of the Exocrine Pancreas.

Authors:  Channabasappa Shivaprasad; Kolla Gautham; Kejal Shah; Soumya Gupta; Preethika Palani; Biswas Anupam
Journal:  J Diabetes Sci Technol       Date:  2020-12-16

Review 7.  Use of sensors in the treatment and follow-up of patients with diabetes mellitus.

Authors:  Isabel Torres; Maria G Baena; Manuel Cayon; Jose Ortego-Rojo; Manuel Aguilar-Diosdado
Journal:  Sensors (Basel)       Date:  2010-08-09       Impact factor: 3.576

8.  Efficacy and safety of insulin lispro in geriatric patients with type 2 diabetes: a retrospective analysis of seven randomized controlled clinical trials.

Authors:  Bradley H Curtis; Tina M Rees; Kim A Gaskins; Justo Sierra-Johnson; Rong Liu; Honghua H Jiang; John H Holcombe
Journal:  Aging Clin Exp Res       Date:  2014-02       Impact factor: 3.636

Review 9.  Drug-related risk of severe hypoglycaemia in observational studies: a systematic review and meta-analysis.

Authors:  Marcin Czech; Elżbieta Rdzanek; Justyna Pawęska; Olga Adamowicz-Sidor; Maciej Niewada; Michał Jakubczyk
Journal:  BMC Endocr Disord       Date:  2015-10-12       Impact factor: 2.763

10.  Major Increases between Pre- and Post-breakfast Glucose Levels May Predict Nocturnal Hypoglycemia in Type 2 Diabetes.

Authors:  Soichi Takeishi; Akihiro Mori; Miyuka Kawai; Yohei Yoshida; Hiroki Hachiya; Takayuki Yumura; Shun Ito; Takashi Shibuya; Nobutoshi Fushimi; Noritsugu Ohashi; Hiromi Kawai
Journal:  Intern Med       Date:  2016-10-15       Impact factor: 1.271

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.