Literature DB >> 20550615

Cryoballoon pulmonary vein isolation supported by intracardiac echocardiography: integration of a nonfluoroscopic imaging technique in atrial fibrillation ablation.

Georg Nölker1, Johannes Heintze, Klaus-Jürgen Gutleben, Bogdan Muntean, Vanessa Pütz, Ameera Yalda, Jürgen Vogt, Dieter Horstkotte.   

Abstract

INTRODUCTION: cryoballoon ablation has been adopted for pulmonary vein (PV) isolation (PVI) in many centers. Complete occlusion of PV by an adequately sized balloon is crucial for effectiveness of cryoenergy delivery. The aim of this study was to evaluate intracardiac echocardiography (ICE) as an alternative imaging technique compared to angiographic imaging in cryoballoon PVI. METHODS AND
RESULTS: a total of 75 PVs were treated in 22 patients (61 ± 13 years, 17 male) undergoing PV cryoballoon ablation for drug refractory paroxysmal atrial fibrillation. Decision for an adequate balloon size was based on diameters of the PV antra assessed by ICE and PV angiography. Per PV 2.4 ± 0.4 cryoenergy pulses were applied. Decision for the balloon size was similar either based upon angiography or on ICE. A single 23 or 28 mm balloon was chosen in 10 and 3 patients, respectively. Two different sized balloons were used in 9 patients. PVI was evaluated after 2 cryoenergy applications. Total occlusion of the PV confirmed by ICE color flow Doppler (CFD) during ablation predicted successful PVI in 70 of 75 (93%) and unsuccessful PVI in 8 of 8 (100%). PV flow registered by pulsed wave Doppler at the PV ostium pre- and postablation was 0.48 ± 0.10 and 0.51 ± 0.12 m/s, respectively (n.s.). PVI was finally confirmed by entrance block in all PVs. No procedural complications occurred.
CONCLUSIONS: ICE is a feasible novel imaging technique in cryoballoon ablation procedures. It allows decision for adequate balloon size, exact balloon placement, prediction of acute ablation success, and excludes acute narrowing of PV ostia.

Entities:  

Mesh:

Year:  2010        PMID: 20550615     DOI: 10.1111/j.1540-8167.2010.01813.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  10 in total

Review 1.  [Ultrasound in the electrophysiological cardiac catheterization laboratory].

Authors:  Klaus-Jürgen Gutleben; Georg Nölker; Nikitas Lironis; Jens Günther
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-12-05

2.  Cryoballoon in atrial fibrillation ablation.

Authors:  M Schmidt; U Dorwarth; F Straube; M Wankerl; J Krieg; A W Leber; A Huber; E Hoffmann
Journal:  Herz       Date:  2012-03       Impact factor: 1.443

3.  Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation.

Authors:  Akihiro Sunaga; Masaharu Masuda; Mitsutoshi Asai; Osamu Iida; Shin Okamoto; Takayuki Ishihara; Kiyonori Nanto; Takashi Kanda; Takuya Tsujimura; Yasuhiro Matsuda; Syota Okuno; Toshiaki Mano
Journal:  J Interv Card Electrophysiol       Date:  2018-04-10       Impact factor: 1.900

Review 4.  Role of Intracardiac echocardiography in Atrial Fibrillation Ablation.

Authors:  Antonio Dello Russo; Eleonora Russo; Gaetano Fassini; Michela Casella; Ester Innocenti; Martina Zucchetti; Claudia Cefalu; Francesco Solimene; Gaetano Mottola; Daniele Colombo; Fabrizio Bologna; Benedetta Majocchi; Pasquale Santangeli; Stefania Riva; Luigi Di Biase; Cesare Fiorentini; Claudio Tondo
Journal:  J Atr Fibrillation       Date:  2013-04-06

Review 5.  Cryoablation of atrial fibrillation.

Authors:  Jonathan P Piccini; James P Daubert
Journal:  J Interv Card Electrophysiol       Date:  2011-08-09       Impact factor: 1.900

Review 6.  Intracardiac Echocardiography in Catheter Ablation for Atrial Fibrillation: It Is Better to See What You Are Doing?

Authors:  Taishi Kuwahara
Journal:  J Atr Fibrillation       Date:  2015-04-30

7.  Hemoptysis as a side effect of cryoballoon pulmonary vein isolation in atrial fibrillation: a retrospective case-control study.

Authors:  Kevin-Gerrit Bullert; Klaus-Jürgen Gutleben; Dieter Horstkotte; Thomas Fischbach; Jan Körfer; Britta Körber; Georg Nölker
Journal:  J Interv Card Electrophysiol       Date:  2018-10-25       Impact factor: 1.900

8.  Usefulness of Contrast Intracardiac Echocardiography in Performing Pulmonary Vein Balloon Occlusion during Cryo-ablation for Atrial Fibrillation.

Authors:  Domenico Catanzariti; Massimiliano Maines; Carlo Angheben; Maurizio Centonze; Claudio Cemin; Giuseppe Vergara
Journal:  Indian Pacing Electrophysiol J       Date:  2012-12-02

9.  Cryoballoon ablation for atrial fibrillation.

Authors:  Jason G Andrade; Marc Dubuc; Peter G Guerra; Laurent Macle; Lena Rivard; Denis Roy; Mario Talajic; Bernard Thibault; Paul Khairy
Journal:  Indian Pacing Electrophysiol J       Date:  2012-04-30

10.  Randomised clinical trial of cryoballoon versus irrigated radio frequency catheter ablation for atrial fibrillation-the effect of double short versus standard exposure cryoablation duration during pulmonary vein isolation (CIRCA-DOSE): methods and rationale.

Authors:  Jason G Andrade; Marc W Deyell; Mariano Badra; Jean Champagne; Marc Dubuc; Peter Leong-Sit; Laurent Macle; Paul Novak; Jean-Francois Roux; John Sapp; Anthony Tang; Atul Verma; George A Wells; Paul Khairy
Journal:  BMJ Open       Date:  2017-10-05       Impact factor: 2.692

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.