OBJECTIVES: The combination of parallel acquisition (generalized autocalibrating partially parallel acquisitions) and time-resolved three-dimensional (3D) view-sharing techniques is a promising tool for dynamic contrast-enhanced 3D-magnetic resonance angiography (MRA). We evaluated the influence of different k-space acquisition strategies on image quality for a recently developed time-resolved echo-shared angiographic technique during a contrast-enhanced 3D-MRA of the thoracic vessels.
MATERIALS AND METHODS: In 20 patients (16 men, 4 women; range, 28-75 years), 2 dynamic MRA protocols with different k-space acquisition strategies were performed on a 1.5-T whole-body scanner (MAGNETOM Avanto, Siemens AG, Erlangen, Germany) during injection of 5 mL (flow-rate, 3 mL/s) gadobutrol. For protocol 1, the central-region which was updated with every cycle included 20% of the entire k-space (protocol 2: 10%), the peripheral-region was undersampled by a factor of 10 (protocol 2: 5%). Image quality and details were compared visually. Signal-to-noise ratio and sharpness of vessel borders were estimated.
RESULTS: Morphologic and functional assessment of the pulmonary arteries and the aorta was significantly improved for protocol 1. The sharpness of vessel borders (3.3 mm vs. 4.1 mm; P = 0.001), image quality, and the visibility of image details were significantly improved for protocol 1 compared with protocol 2.
CONCLUSION: The size of the central region that is updated for every frame seems to be more crucial for image quality of echo-shared angiographic techniques than the sampling density in the periphery of the k-space.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20548241     DOI: 10.1097/RLI.0b013e3181e5bbb0

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  [MRI for therapy control in patients with aortic isthmus stenosis].

Authors:  B J Wintersperger; D Theisen; M F Reiser
Journal:  Radiologe       Date:  2011-01       Impact factor: 0.635

2.  Buildup of image quality in view-shared time-resolved 3D CE-MRA.

Authors:  Casey P Johnson; Thomas W Polley; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2012-08-30       Impact factor: 4.668

Review 3.  Cardiovascular sources of systemic embolism: detection and characterization using multidetector CT and MR imaging.

Authors:  Jiyoung Hwang; Yeon Hyeon Choe
Journal:  Int J Cardiovasc Imaging       Date:  2011-05-03       Impact factor: 2.357

4.  Technical innovation in dynamic contrast-enhanced magnetic resonance imaging of musculoskeletal tumors: an MR angiographic sequence using a sparse k-space sampling strategy.

Authors:  Laura M Fayad; Charles Mugera; Theodoros Soldatos; Aaron Flammang; Filippo del Grande
Journal:  Skeletal Radiol       Date:  2013-04-05       Impact factor: 2.199

5.  Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA.

Authors:  Florian M Vogt; Jens M Theysohn; Dariusz Michna; Peter Hunold; Ulrich Neudorf; Sonja Kinner; Jörg Barkhausen; Harald H Quick
Journal:  Eur Radiol       Date:  2013-05-04       Impact factor: 5.315