Literature DB >> 20546795

Influence of the On-X mechanical prosthesis on intermediate-term major thromboembolism and hemorrhage: a prospective multicenter study.

Vincent Chan1, W R Eric Jamieson, B-Khanh Lam, Marc Ruel, Hilton Ling, Guy Fradet, Thierry G Mesana.   

Abstract

OBJECTIVES: Long-term thromboembolic and hemorrhagic outcomes after mechanical valve replacement have been well described; however, few studies have described these outcomes after valve replacement with the On-X mechanical prosthesis (On-X Life Technologies, Inc, Austin, Tex).
METHODS: Between 2003 and 2008, 737 patients underwent either aortic valve replacement (n = 400), mitral valve replacement (n = 282), or double-valve replacement (n = 55). Longitudinal performance, freedom evaluation, and risk analysis were assessed with regard to major thromboembolism and hemorrhage. Risk modeling was performed with 16 variables inclusive of age, atrial fibrillation, concomitant coronary artery bypass grafting, New York Heart Association class, and ventricular dysfunction.
RESULTS: Early mortality was 2.5% (n = 10) for aortic valve replacement and 3.2% (n = 9) for mitral valve replacement. Late mortality for aortic valve replacement was 4.8% per patient-year and 6.0% per patient-year for mitral valve replacement. Five-year freedom from major thromboembolism was 96.5% ± 1.2% for aortic valve replacement and 97.7% ± 0.9% for mitral valve replacement. Five-year freedom from hemorrhage was 93.6% ± 1.8% for aortic valve replacement and 95.7% ± 1.5% for mitral valve replacement. Concomitant coronary artery bypass grafting was predictive of major thromboembolism after aortic valve replacement (hazard ratio, 5.3; P = .02) and antithrombotic hemorrhage after mitral valve replacement (hazard ratio, 4.7; P = .03). No other independent predictors of major thromboembolism or hemorrhage were identified. One thrombosed mitral prosthesis was observed after deliberate discontinuation of anticoagulation. The major thromboembolic events occurred with variation of international normalized ratio levels inclusive of subtherapeutic levels. The majority of hemorrhagic events occurred with high international normalized ratio levels.
CONCLUSIONS: The On-X mechanical prosthesis provides favorable intermediate-term results with regard to major thromboembolism and hemorrhage.
Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20546795     DOI: 10.1016/j.jtcvs.2009.10.068

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  7 in total

1.  10-year results of On-X bileaflet mechanical heart valve in the aortic position: low target INR regimen in Japanese.

Authors:  Hideki Teshima; Masahiko Ikebuchi; Yosuke Miyamoto; Ryuta Tai; Toshikazu Sano; Yusuke Kinugasa; Hiroyuki Irie
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-04-19

2.  Aortic biological valve prosthesis in patients younger than 65 years of age: transition to a flexible age limit?

Authors:  Lars Niclauss; Ludwig Karl von Segesser; Enrico Ferrari
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-01-03

3.  Hemorrhage as a life-threatening complication after valve replacement in end-stage renal disease patients.

Authors:  Taro Nakatsu; Nobushige Tamura; Shigeki Yanagi; Shoichi Kyo; Takaaki Koshiji; Ryuzo Sakata
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-04-19

Review 4.  Advances in the management of severe aortic stenosis.

Authors:  K E O'Sullivan; S Bargenda; D Sugrue; J Hurley
Journal:  Ir J Med Sci       Date:  2016-02-17       Impact factor: 1.568

5.  Anticoagulation dilemma in a high-risk patient with On-X valves.

Authors:  Ami M Karkar; Manuel R Castresana; Nadine Odo; Shvetank Agarwal
Journal:  Ann Card Anaesth       Date:  2015 Apr-Jun

6.  Successful Explantation of a Ball and Cage Mitral Valve Prosthesis 48 Years After Initial Implantation.

Authors:  Kenza Rahmouni; Justendra Naidu; Neil Pearce; Vincent Chan
Journal:  CJC Open       Date:  2021-11-21

7.  On-X versus St Jude Medical Regent mechanical aortic valve prostheses: early haemodynamics.

Authors:  Robert Xu; Mohammad Rahnavardi; Bradley Pitman; Masoumeh Shirazi; Robert Stuklis; James Edwards; Michael Worthington
Journal:  Open Heart       Date:  2017-02-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.