Literature DB >> 20546675

Platelet Adhesion and Fibrinogen Accretion on a Family of Elastin-Like Polypeptides.

E M Srokowski1, P H Blit, W G McClung, J L Brash, J P Santerre, K A Woodhouse.   

Abstract

Previous work in our laboratory showed the potential of using a human recombinant elastin-like polypeptide (ELP) as a thromboresistant coating. In this work we investigate the use of three particular ELPs (ELP1, ELP2 and ELP4), that differ by molecular weight and number of repeating hydrophobic and cross-linking domains, as coatings to improve blood-contacting properties. All three ELPs were passively adsorbed on Mylar surfaces. Differences in water contact angle and surface concentration were found among the three ELP coatings, with the shortest polypeptide, ELP1, being the most hydrophilic and abundant on the surface (55°, 0.76 μg/cm(2)), followed by ELP2 (55°, 0.35 μg/cm(2)) and ELP4, the longest of the three (66°, 0.25 μg/cm(2)), respectively. The blood interactions of the ELP coatings were investigated by measuring fibrinogen adsorption and platelet adhesion in whole blood under laminar flow in a cone and plate viscometer configuration. In general, platelet adhesion to the ELP-coated surfaces was found to correlate with fibrinogen adsorption. Decreases in fibrinogen accretion and platelet adhesion were observed for ELP-coated compared to uncoated surfaces. The magnitude of the decreases was found to depend on the ELP sequence length, with ELP4 exhibiting the lowest levels of fibrinogen adsorption and platelet adhesion at 43 ± 24 ng/cm(2) and 113 ± 77 platelets/mm(2), respectively.

Entities:  

Keywords:  BLOOD COMPATIBILITY; ELASTIN-LIKE POLYPEPTIDES; FIBRINOGEN ADSORPTION; PLATELET ADHESION

Mesh:

Substances:

Year:  2011        PMID: 20546675     DOI: 10.1163/092050609X12578498935594

Source DB:  PubMed          Journal:  J Biomater Sci Polym Ed        ISSN: 0920-5063            Impact factor:   3.517


  4 in total

1.  Nanotoxicology of an Elastin-like Polypeptide Rapamycin Formulation for Breast Cancer.

Authors:  Santosh Peddi; S Kenny Roberts; John Andrew MacKay
Journal:  Biomacromolecules       Date:  2020-02-06       Impact factor: 6.988

2.  Electrospun fiber constructs for vocal fold tissue engineering: effects of alignment and elastomeric polypeptide coating.

Authors:  Lindsay A Hughes; Joel Gaston; Katherine McAlindon; Kimberly A Woodhouse; Susan L Thibeault
Journal:  Acta Biomater       Date:  2014-11-04       Impact factor: 8.947

3.  Surface and adsorption characteristics of three elastin-like polypeptide coatings with varying sequence lengths.

Authors:  Elizabeth M Srokowski; Kimberly A Woodhouse
Journal:  J Mater Sci Mater Med       Date:  2012-09-30       Impact factor: 3.896

4.  Role of cell-matrix interactions on VIC phenotype and tissue deposition in 3D PEG hydrogels.

Authors:  Sarah T Gould; Kristi S Anseth
Journal:  J Tissue Eng Regen Med       Date:  2013-10-16       Impact factor: 3.963

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.