Removal of exhaled particles by ventilation and deposition in a multibed airborne infection isolation room.

H Qian1, Y Li.   

Abstract

UNLABELLED: Removal of airborne particles in airborne infection isolation rooms is important for infection control of airborne diseases. Previous studies showed that the downward ventilation recommended by Centers for Disease Control and Prevention (CDC) could not produce the expected 'laminar' flow for pushing down respiratory gaseous contaminants and removing them via floor-level exhausts. Instead, upper-level exhausts were more efficient in removing gaseous contaminants because of upward body plumes. The conventional wisdom in the current CDC-recommended design is that floor-level exhausts may efficiently remove large droplets/particles, but such a hypothesis has not been proven. We investigated the fate of respiratory particles in a full-scale six-bed isolation room with exhausts at different locations by both experimental and computational studies. Breathing thermal manikins were used to simulate patients, and both gaseous and large particles were used to simulate the expelled fine droplet nuclei and large droplets. Gaseous and fine particles were found to be removed more efficiently by ceiling-level exhausts than by floor-level exhausts. Large particles were mainly removed by deposition rather than by ventilation. Our results show that the existing isolation room ventilation design is not effective in removing both fine and large respiratory particles. An improved ventilation design is hence recommended. PRACTICAL IMPLICATIONS: Our findings of the relatively poor performance of fine-particle removal by the existing CDC design of isolation room ventilation suggests a need for improvement, and the findings of the removal of large particles by deposition, not by ventilation, suggest that floor-level exhausts are unnecessary, and that regular surface cleaning and disinfection is necessary, thus providing evidence for maintaining isolation room surface hygiene.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20546037     DOI: 10.1111/j.1600-0668.2010.00653.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  19 in total

Review 1.  Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.

Authors:  Hua Qian; Xiaohong Zheng
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

2.  Transmission of pathogen-laden expiratory droplets in a coach bus.

Authors:  Xia Yang; Cuiyun Ou; Hongyu Yang; Li Liu; Tie Song; Min Kang; Hualiang Lin; Jian Hang
Journal:  J Hazard Mater       Date:  2020-04-12       Impact factor: 10.588

Review 3.  Ventilation strategies to reduce airborne transmission of viruses in classrooms: A systematic review of scientific literature.

Authors:  S Ferrari; T Blázquez; R Cardelli; G Puglisi; R Suárez; L Mazzarella
Journal:  Build Environ       Date:  2022-07-07       Impact factor: 7.093

4.  Dispersion and exposure to a cough-generated aerosol in a simulated medical examination room.

Authors:  William G Lindsley; William P King; Robert E Thewlis; Jeffrey S Reynolds; Kedar Panday; Gang Cao; Jonathan V Szalajda
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

Review 5.  Safety and Reverence: How Roman Catholic Liturgy Can Respond to the COVID-19 Pandemic.

Authors:  Sergey Budaev
Journal:  J Relig Health       Date:  2021-05-24

6.  Impact of air-handling system exhaust failure on dissemination pattern of simulant pathogen particles in a clinical biocontainment unit.

Authors:  Jennifer Therkorn; David Drewry Iii; Thomas Pilholski; Kathryn Shaw-Saliba; Gregory Bova; Lisa L Maragakis; Brian Garibaldi; Lauren Sauer
Journal:  Indoor Air       Date:  2018-10-05       Impact factor: 5.770

7.  Possible role of aerosol transmission in a hospital outbreak of influenza.

Authors:  Bonnie C K Wong; Nelson Lee; Yuguo Li; Paul K S Chan; Hong Qiu; Zhiwen Luo; Raymond W M Lai; Karry L K Ngai; David S C Hui; K W Choi; Ignatius T S Yu
Journal:  Clin Infect Dis       Date:  2010-10-13       Impact factor: 9.079

8.  Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital ward.

Authors:  Xiangfei Kong; Chenli Guo; Zhang Lin; Shasha Duan; Junjie He; Yue Ren; Jianlin Ren
Journal:  Sustain Cities Soc       Date:  2021-06-17       Impact factor: 7.587

9.  High humidity leads to loss of infectious influenza virus from simulated coughs.

Authors:  John D Noti; Francoise M Blachere; Cynthia M McMillen; William G Lindsley; Michael L Kashon; Denzil R Slaughter; Donald H Beezhold
Journal:  PLoS One       Date:  2013-02-27       Impact factor: 3.240

10.  Airflow patterns through single hinged and sliding doors in hospital isolation rooms - Effect of ventilation, flow differential and passage.

Authors:  Petri Kalliomäki; Pekka Saarinen; Julian W Tang; Hannu Koskela
Journal:  Build Environ       Date:  2016-07-15       Impact factor: 6.456