Dialysate and blood temperature during hemodialysis: comparing isothermic dialysis with a single-pass batch system.

Annemieke Dhondt1, Sunny Eloot, Francis Verbeke, Raymond Vanholder.   

Abstract

The Genius is a convenient single-pass batch hemodialysis system. Dialysate is heated during the preparation phase. Once the container is filled at one of the three available starting temperatures, dialysate cools spontaneously. As dialysate temperature plays an important role in hemodynamic stability, knowledge of the instantaneous dialysate temperature is important. We documented the evolution of dialysate temperature during Genius dialysis with dialysate prepared at two different temperatures (low and medium) as well as its effect on blood temperature and hemodynamic stability. Genius dialysis was compared to isothermic dialysis obtained by a module programmed to obtain a constant blood temperature. With Genius, dialysate temperature progressively decreased from 36.3 (low) and 37.6°C (medium) in the beginning to 34.4 and 35.3°C at the end of the session, both following first-order kinetics. During isothermic dialysis, dialysate cooled from 37.3 to 35.4°C, being warmer than with Genius low. Blood temperature decreased during dialysis with Genius low, from 36.4 to 36.2°C, whereas with medium temperature, blood temperature initially rose from 36.4°C at 15 min to 36.5 and 36.6°C at 30 and 60 min, respectively, followed by a decrease from 180 min onward, to 36.4°C at the end. During isothermic dialysis, blood temperature remained stable, as expected. Blood pressure decreased during all three schedules, with the highest value at 15 min during isothermic dialysis, and at the end of the session, the lowest value with isothermic dialysis.
© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Mesh:

Substances:

Year:  2010        PMID: 20545670     DOI: 10.1111/j.1525-1594.2009.00981.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

Review 1.  Effect of Lowering the Dialysate Temperature in Chronic Hemodialysis: A Systematic Review and Meta-Analysis.

Authors:  Reem A Mustafa; Fadi Bdair; Elie A Akl; Amit X Garg; Heather Thiessen-Philbrook; Hassan Salameh; Sood Kisra; Gihad Nesrallah; Ahmad Al-Jaishi; Parth Patel; Payal Patel; Ahmad A Mustafa; Holger J Schünemann
Journal:  Clin J Am Soc Nephrol       Date:  2015-12-28       Impact factor: 8.237

2.  Total collected dialysate lithium concentration after successful dialysis treatment in case of intoxication.

Authors:  Julius J Schmidt; Johan Lorenzen; Christos Chatzikyrkou; Ralf Lichtinghagen; Jan T Kielstein
Journal:  BMC Pharmacol Toxicol       Date:  2014-09-06       Impact factor: 2.483

3.  Evaluation of Intermittent Hemodialysis in Critically Ill Cancer Patients with Acute Kidney Injury Using Single-Pass Batch Equipment.

Authors:  Verônica Torres da Costa E Silva; Elerson C Costalonga; Ana Paula Leandro Oliveira; James Hung; Renato Antunes Caires; Ludhmila Abrahão Hajjar; Julia T Fukushima; Cilene Muniz Soares; Juliana Silva Bezerra; Luciane Oikawa; Luis Yu; Emmanuel A Burdmann
Journal:  PLoS One       Date:  2016-03-03       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.