Literature DB >> 20545552

Implant-retained mandibular bar-supported overlay dentures: a finite element stress analysis of four different bar heights.

Mansoor Rismanchian1, Mansour Dakhilalian, Farshad Bajoghli, Ehsan Ghasemi, Pooyan Sadr-Eshkevari.   

Abstract

Proper stress distribution on dental implants is necessary in bar-retained implant overlay dentures. We aimed to comparatively assess this stress distribution according to different bar heights using finite element models. A three-dimensional (3D) computer model of mandible with 2 implants (ITI, 4.1 mm diameter and 12 mm length) in canine areas and an overlying implant-supported bar-retained overlay denture were simulated with 0-, 1-, 2-, and 3-mm bar heights using ABAQUS software. A vertical force was applied to the left first molar and gradually increased from 0 to 50 N. The resultant stress distribution was evaluated. Bars of 1 and 2 mm in height transferred the least stress to the implants (3.882 and 3.896 MPa, respectively). The 0-mm height of the bar connection transferred the highest stress value (4.277 MPa). The amount of stress transferred by 3-mm heights of the bar connection was greater than that of 1- and 2-mm bar connections and smaller than that of 0-mm bar connection (4.165 kgN). This 3D finite element analysis study suggested that the use of Dolder bar attachment with 1- and 2-mm heights could be associated with appropriate stress distribution for implant-retained overlay dentures.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20545552     DOI: 10.1563/AAID-JOI-D-09-00037.1

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis.

Authors:  Mostafa Omran Hussein
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

2.  Implant-supported bar overdentures in patients treated surgically for head and neck cancer: Two case reports.

Authors:  Nadine Omeish; Benjamin Pomes; Hélène Citterio
Journal:  Clin Case Rep       Date:  2022-03-01

3.  Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis.

Authors:  Behnaz Ebadian; Mahmoud Farzin; Saeid Talebi; Niloufar Khodaeian
Journal:  Dent Res J (Isfahan)       Date:  2012-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.