Literature DB >> 20544613

One center experience in pulmonary artery stenting without long vascular sheath.

Tomasz Moszura1, Krzysztof W Michalak, Paweł Dryzek, Jadwiga A Moll, Jacek Moll, Andrzej Sysa.   

Abstract

BACKGROUND: Pulmonary artery stenting without a long vascular sheath has a special significance, particularly for children with low body weight. Using only a short sheath often permits the implantion of a stent of the correct size; moreover, it improves access to peripherally located stenoses. The aim of this paper is to present the results of a balloon expandable stent implantation into pulmonary arteries without using a long vascular sheath.
METHODS: The subjects were divided into two groups. The first group (28 patients, mean age 3.2 years) comprised patients with a single-ventricle heart after bi-directional Glenn procedure (Fontan procedure). The second group (22 patients, mean age 8.3 years) consisted of patients with a two-ventricle heart. Patients were retrospectively analyzed with regard to stenosis size widening and change in trans-stenotic pressure gradient after stenting.
RESULTS: In our data, no statistically significant differences between the two groups in terms of the number of complications and incorrect stent position following implantation were noted (3% and 4%). Good treatment results, with a decrease in trans-stenotic pressure gradient in the first group of 3.2 mm and in the second group of 13.4 mm of mercury, and a widening of the stenosis, were obtained in most cases in both groups (97% and 96%). The average change of the vessel's diameter was in the first group 4.2 mm and in the second 5.4 mm.
CONCLUSIONS: The obtained results suggest that pulmonary artery stenting with a short vascular sheath has numerous advantages and can be successfully performed in children. In the case of single-ventricle hearts after a Glenn procedure, it may indeed be the method of choice.

Entities:  

Mesh:

Year:  2010        PMID: 20544613

Source DB:  PubMed          Journal:  Cardiol J        ISSN: 1898-018X            Impact factor:   2.737


  2 in total

1.  Effectiveness and safety of percutaneous transcatheter implantation of pulmonary arterial stent in congenital heart disease.

Authors:  Hong Ki Ko; Young-Hwue Kim; Jeong Jin Yu; Jae-Kon Ko; In-Sook Park; Dong-Man Seo; Tae-Jin Yun; Jeong-Jun Park; Wan Sook Jang
Journal:  Korean Circ J       Date:  2012-01-31       Impact factor: 3.243

2.  Medium and long-term outcomes after bilateral pulmonary artery stenting in children and adults with congenital heart disease.

Authors:  Ismael Gonzalez; Damien Kenny; Shari Slyder; Ziyad M Hijazi
Journal:  Pediatr Cardiol       Date:  2012-07-28       Impact factor: 1.655

  2 in total