Literature DB >> 20544241

New pre-clotting method for fibrin glue in a non-sealed graft used in an LVAD: the KYO method.

Motoyuki Hisagi1, Takashi Nishimura, Minoru Ono, Satoshi Gojo, Kan Nawata, Shunei Kyo.   

Abstract

Pre-clotting has been applied to a vascular prosthesis with high permeability (non-sealed graft). In this study, conventional pre-clotting methods were compared with our novel method, which keeps high-yield optimization of hemostasis, the KYO method. Fibrinogen solution (A) and thrombin solution (B) of fibrin glue (Beriplast P Combi-Set(®)) were applied to the graft (Cooly low-porosity woven graft) by five methods; Group 1: control, without fibrin glue; Group 2: spray method, spraying solutions A and B simultaneously; Group 3: rub method, rubbing solution A first, and then rubbing solution B on the graft; Group 4: rub-and-spray method, rubbing solution A on the graft, then spraying solutions A and B; Group 5: the KYO method, rubbing solution A into the graft with the finger, then rubbing solution B on the graft. Burst pressure, the point of saline solution leakage, was measured 10 times for each group. The grafts were microscopically examined using HE staining and electron microscopy. The average burst pressure was 12.6 ± 1.5 mmHg in Group 1, 27.1 ± 3.3 mmHg in Group 2, 22.4 ± 7.1 mmHg in Group 3, 41.0 ± 9.0 mmHg in Group 4, and 300 mmHg in Group 5. Saline solution did not leak through the graft at a pressure of 300 mmHg in Group 5. There were statistically significant differences among the groups. The relationship between fibrin glue and the graft was unclear in all groups by HE staining. Electron microscopic photographs showed a smooth surface and fibrin glue permeating the graft fibers in Group 5. The KYO method was better than the others in terms of resistance to pressure. It was a very simple method, and could thus come into widespread use.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20544241     DOI: 10.1007/s10047-010-0504-1

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  4 in total

1.  Evaluation of fibrin sealing for cardiovascular surgery.

Authors:  H Jakob; C D Campbell; Z K Qiu; R Pick; R L Replogle
Journal:  Circulation       Date:  1984-09       Impact factor: 29.690

2.  New application method of fibrin glue for more effective hemostasis in cardiovascular surgery: rub-and-spray method.

Authors:  Naoki Minato; Tomoki Shimokawa; Yuji Katayama; Noriko Yamada; Masayuki Sakaguchi; Manabu Itoh
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2004-08

3.  Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve.

Authors:  N T Kouchoukos; W G Marshall; T A Wedige-Stecher
Journal:  J Thorac Cardiovasc Surg       Date:  1986-10       Impact factor: 5.209

4.  A quantitative and qualitative comparison of fibrin glue, albumin, and blood as agents to pretreat porous vascular grafts.

Authors:  S R Gundry; D M Behrendt
Journal:  J Surg Res       Date:  1987-07       Impact factor: 2.192

  4 in total
  2 in total

Review 1.  Journal of Artificial Organs 2010: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2011-03-16       Impact factor: 1.731

2.  Expanding perigraft seroma after ascending aorta replacement.

Authors:  Shinji Kanemitsu; Shunsuke Sakamoto; Satoshi Teranishi; Toru Mizumoto
Journal:  J Cardiothorac Surg       Date:  2022-10-04       Impact factor: 1.522

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.