Literature DB >> 20542810

Micro-computed tomographic assessment following extremely oversized partial postdilatation of drug-eluting stents.

Mounir W Z Basalus1, K Gert van Houwelingen, Marc J K Ankone, Jan Feijen, Clemens von Birgelen.   

Abstract

AIMS: To assess the spatial geometry of drug-eluting stents (DES) following extremely oversized proximal postdilatation. Interventions of distal left main (LM) disease generally require stenting across the LM bifurcation with inherent vessel tapering along this segment and a high likelihood of stent malapposition, which can be avoided by such postdilations. METHODS AND
RESULTS: Sixteen DES (four 3.5 mm-samples of Cypher Select Plus, Taxus Liberté, Endeavor Resolute, Xience V) were deployed in water; 12 samples were then proximally postdilated with noncompliant 5.0 mm balloons at 18 atm. All samples were examined by micro-computed tomography. Taxus Liberté, Endeavor Resolute, and Xience V, showed increased cell areas in the transitional region (just distal to postdilated region), while Cypher Select showed its largest cells inside the postdilated region. Overall, the largest maximum cell area was observed in Endeavor Resolute, while Cypher Select showed the smallest (p<0.001, for both). In addition, the size of the very proximal postdilated cells was relatively small in most DES except Xience V.
CONCLUSIONS: Extremely oversized partial stent postdilatation demonstrated significant between-DES differences in final spatial stent configuration and maximum cell size. These data could be of practical interest with regard to coronary interventions in LM stems with stenting across the LM bifurcation.

Entities:  

Mesh:

Year:  2010        PMID: 20542810     DOI: 10.4244/

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  6 in total

Review 1.  Update on Provisional Technique for Bifurcation Interventions.

Authors:  Lazzaro Paraggio; Francesco Burzotta; Cristina Aurigemma; Carlo Trani
Journal:  Curr Cardiol Rep       Date:  2016-03       Impact factor: 2.931

2.  The Proximal Optimisation Technique for Intervention of Coronary Bifurcations.

Authors:  Angela Hoye
Journal:  Interv Cardiol       Date:  2017-09

3.  Technical Aspects of Provisional Stenting in Percutaneous Treatment of Complex Bifurcation Lesions.

Authors:  Francesco Burzotta; Carlo Trani
Journal:  Interv Cardiol       Date:  2013-08

Review 4.  Stenting of coronary bifurcation lesions: a literature and technical review.

Authors:  Joo Myung Lee; Kyung Woo Park; Bon-Kwon Koo; Hyo-Soo Kim
Journal:  Curr Cardiol Rep       Date:  2015-06       Impact factor: 2.931

5.  Ultrasound and light: friend or foe? On the role of intravascular ultrasound in the era of optical coherence tomography.

Authors:  Jennifer Huisman; Marc Hartmann; Clemens von Birgelen
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-20       Impact factor: 2.357

6.  Expansion of the Multi-Link Frontier™ coronary bifurcation stent: micro-computed tomographic assessment in human autopsy and porcine heart samples.

Authors:  Stefan Kralev; Benjamin Haag; Jens Spannenberger; Siegfried Lang; Marc A Brockmann; Soenke Bartling; Alexander Marx; Karl-Konstantin Haase; Martin Borggrefe; Tim Süselbeck
Journal:  PLoS One       Date:  2011-07-21       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.