Literature DB >> 20542486

The use of titanium T-plate as platform for globe alignment in severe paralytic and restrictive strabismus.

David T Tse1, Erin M Shriver, Kenneth B Krantz, Jeffrey D Tse, Hilda Capo, Craig A McKeown.   

Abstract

PURPOSE: To evaluate the long-term effectiveness of improved ocular alignment using a suture/T-plate anchoring platform system.
DESIGN: Retrospective, noncomparative, interventional case series.
METHODS: setting: Institutional. study population: Seven consecutive patients with large angle deviations attributable to paralytic and/or restrictive strabismus managed jointly by orbital and strabismus surgeons. intervention procedure: The T-plate base is anchored to the orbital rim with the shaft projecting toward the orbital apex to simulate the origin of the affected muscle. A nonabsorbable suture serves as the coupling element linking the muscle insertion to the tip of the T-plate such that the suture coincides with the axis of the dysfunctional muscle and yields a pull vector to simulate the passive tensile force of the muscle. Information analyzed included patient demographics, etiology of strabismus and characteristics, prior muscle surgeries, secondary interventions, subjective appraisal of diplopia, and final ocular alignment measurements. main outcome measures: Subjective appraisal of diplopia, final ocular alignment in primary gaze, and late stability.
RESULTS: All 7 patients showed marked reduction in ocular deviation with a median change of 33 prism diopters (PD) and a range of 7 to 72 PD. For the 6 patients with medial rectus dysfunction, the final ocular alignment ranged from 6 to 18 PD of residual exotropia in primary gaze. The patient with sixth nerve palsy had 5 PD of residual esotropia. There were no failures after an average of 59.4 months of follow-up.
CONCLUSIONS: A globe tethering technique using a suture/titanium T-plate anchoring platform system effectively treats refractory cases of paralytic and restrictive strabismus with large angles of deviation. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20542486     DOI: 10.1016/j.ajo.2010.03.029

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  3 in total

1.  Splitting of the lateral rectus muscle with medial transposition to treat oculomotor palsy: a retrospective analysis of 29 consecutive cases.

Authors:  Sotirios Basiakos; Michael Gräf; Markus N Preising; Birgit Lorenz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-06-06       Impact factor: 3.117

2.  Extraocular muscle injury during endoscopic sinus surgery: an ophthalmologic perspective.

Authors:  K-A Park; S Y Oh
Journal:  Eye (Lond)       Date:  2016-02-19       Impact factor: 3.775

Review 3.  Periosteal Fixation Procedures in the Management of Incomitant Strabismus.

Authors:  Rohit Saxena; Swati Phuljhele; Pradeep Sharma; C N Pinto
Journal:  Middle East Afr J Ophthalmol       Date:  2015 Jul-Sep
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.