Literature DB >> 20542313

Organic micropollutant removal from wastewater effluent-impacted drinking water sources during bank filtration and artificial recharge.

Sung Kyu Maeng1, Emmanuel Ameda, Saroj K Sharma, Gesche Grützmacher, Gary L Amy.   

Abstract

Natural treatment systems such as bank filtration (BF) and artificial recharge (via an infiltration basin) are a robust barrier for many organic micropollutants (OMPs) and may represent a low-cost alternative compared to advanced drinking water treatment systems. This study analyzes a comprehensive database of OMPs at BF and artificial recharge (AR) sites located near Lake Tegel in Berlin (Germany). The focus of the study was on the derivation of correlations between the removal efficiencies of OMPs and key factors influencing the performance of BF and AR. At the BF site, shallow monitoring wells located close to the Lake Tegel source exhibited oxic conditions followed by prolonged anoxic conditions in deep monitoring wells and a production well. At the AR site, oxic conditions prevailed from the recharge pond along monitoring wells to the production well. Long residence times of up to 4.5 months at the BF site reduced the temperature variation during soil passage between summer and winter. The temperature variations were greater at the AR site as a consequence of shorter residence times. Deep monitoring wells and the production well located at the BF site were under the influence of ambient groundwater and old bank filtrate (up to several years of age). Thus, it is important to account for mixing with native groundwater and other sources (e.g., old bank filtrate) when estimating the performance of BF with respect to removal of OMPs. Principal component analysis (PCA) was used to investigate correlations between OMP removals and hydrogeochemical conditions with spatial and temporal parameters (e.g., well distance, residence time and depth) from both sites. Principal component-1 (PC1) embodied redox conditions (oxidation-reduction potential and dissolved oxygen), and principal component-2 (PC2) embodied degradation potential (e.g., total organic carbon and dissolved organic carbon) with the calcium carbonate dissolution potential (Ca(2+) and HCO(3)(-)) for the BF site. These two PCs explained a total variance of 55% at the BF site. At the AR site, PCA revealed redox conditions (PC1) and degradation potential with temperature (PC2) as principal components, which explained a total variance of 56%. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20542313     DOI: 10.1016/j.watres.2010.03.035

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  Behavior of nine selected emerging trace organic contaminants in an artificial recharge system supplemented with a reactive barrier.

Authors:  Cristina Valhondo; Jesús Carrera; Carlos Ayora; Manuela Barbieri; Karsten Nödler; Tobias Licha; Maria Huerta
Journal:  Environ Sci Pollut Res Int       Date:  2014-05-06       Impact factor: 4.223

2.  Prokaryotic and Viral Community Composition of Freshwater Springs in Florida, USA.

Authors:  Kema Malki; Karyna Rosario; Natalie A Sawaya; Anna J Székely; Michael J Tisza; Mya Breitbart
Journal:  mBio       Date:  2020-04-07       Impact factor: 7.867

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.