Literature DB >> 20541949

Efficacy and safety of TachoSil® versus standard treatment of air leakage after pulmonary lobectomy.

Gabriel Mihai Marta1, Francesco Facciolo, Lars Ladegaard, Hendrik Dienemann, Attila Csekeo, Federico Rea, Sebastian Dango, Lorenzo Spaggiari, Vilhelm Tetens, Walter Klepetko.   

Abstract

OBJECTIVES: Alveolar air leakage remains a serious problem in lung surgery, being associated with increased postoperative morbidity, prolonged hospital stay and greater health-care costs. The aim of this study was to evaluate the sealing efficacy and safety of the surgical patch, TachoSil®, in lung surgery.
METHODS: Patients undergoing elective pulmonary lobectomy who had grade 1 or 2 air leakage (evaluated by the water submersion test) after primary stapling and limited suturing were randomised at 12 European centres to open-label treatment with TachoSil® or standard surgical treatment (resuturing, stapling or no further treatment at the surgeons' discretion). Randomisation was performed during surgery using a centralised interactive voice response system. Duration of postoperative air leakage (primary end point), reduction of intra-operative air leakage intensity (secondary end point) and adverse events (AEs), including postoperative complications, were assessed.
RESULTS: A total of 486 patients were screened and 299 received trial treatment (intent-to-treat (ITT) population: TachoSil®, n=148; standard treatment, n=151). TachoSil® resulted in a reduction in the duration of postoperative air leakage (p=0.030). Patients in the TachoSil® group also experienced a greater reduction in intra-operative air leakage intensity (p=0.042). Median time until chest drain removal was 4 days with TachoSil® and 5 days in the standard group (p=0.054). There was no difference between groups in hospital length of stay. AEs were generally similar in both groups, including postoperative complications.
CONCLUSIONS: TachoSil® was superior to standard surgical treatment in reducing both postoperative air leakage duration and intra-operative air leakage intensity in patients undergoing elective pulmonary lobectomy.
Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20541949     DOI: 10.1016/j.ejcts.2010.03.061

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  19 in total

1.  Management of unexpected intraoperative bleeding during thoracoscopic pulmonary resection: a single institutional experience.

Authors:  Takuro Miyazaki; Naoya Yamasaki; Tomoshi Tsuchiya; Keitaro Matsumoto; Go Hatachi; Yuka Kitamura; Tomohiro Obata; Ryoichiro Doi; Ryusuke Machino; Takeshi Nagayasu
Journal:  Surg Today       Date:  2015-09-28       Impact factor: 2.549

2.  Efficacy and safety of human fibrinogen-thrombin patch (Tachosil(®)) in the management of diffuse bleeding after chest wall and spinal surgical resection for aggressive thoracic neoplasms.

Authors:  Pier Luigi Filosso; Francesco Guerrera; Alberto Sandri; Francesco Zenga; Giovanni Vittorio Lanza; Enrico Ruffini; Giulia Bora; Paraskevas Lyberis; Paolo Solidoro; Alberto Oliaro
Journal:  J Thorac Dis       Date:  2016-01       Impact factor: 2.895

Review 3.  Use of local pro-coagulant haemostatic agents for intra-cavity control of haemorrhage after trauma.

Authors:  A Navarro; A Brooks
Journal:  Eur J Trauma Emerg Surg       Date:  2014-08-26       Impact factor: 3.693

4.  The utility of BiClamp(®) for intraoperative air leakage control in video-assisted thoracic surgery for pulmonary lobectomy.

Authors:  Tohru Sakuragi; Hitoshi Ohteki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-07-13

Review 5.  Systematic review on the use of matrix-bound sealants in pancreatic resection.

Authors:  F Jasmijn Smits; Hjalmar C van Santvoort; Marc G H Besselink; Inne H M Borel Rinkes; I Quintus Molenaar
Journal:  HPB (Oxford)       Date:  2015-08-21       Impact factor: 3.647

6.  From surgery to neurosurgery: our experience on the efficacy of fleece-bound sealing (TachoSil®) for dural repair.

Authors:  S Ulivieri; G Peri; G Tiezzi; E Mileo; A Giorgio; G Oliveri
Journal:  G Chir       Date:  2014 Jul-Aug

Review 7.  Effectiveness of Tachosil(®) in the prevention of postoperative pancreatic fistula after distal pancreatectomy: a systematic review and meta-analysis.

Authors:  Felix J Hüttner; André L Mihaljevic; Thilo Hackert; Alexis Ulrich; Markus W Büchler; Markus K Diener
Journal:  Langenbecks Arch Surg       Date:  2016-02-20       Impact factor: 3.445

Review 8.  Clinical applications of naturally derived biopolymer-based scaffolds for regenerative medicine.

Authors:  Whitney L Stoppel; Chiara E Ghezzi; Stephanie L McNamara; Lauren D Black; David L Kaplan
Journal:  Ann Biomed Eng       Date:  2014-12-24       Impact factor: 3.934

9.  Efficacy and safety of human fibrinogen-thrombin patch (TachoSil®) in the treatment of postoperative air leakage in patients submitted to redo surgery for lung malignancies: a randomized trial.

Authors:  Pier Luigi Filosso; Enrico Ruffini; Alberto Sandri; Paolo Olivo Lausi; Roberto Giobbe; Alberto Oliaro
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-02-17

10.  Feedback on the use of three surgical sealants for preventing prolonged air leak after robot-assisted anatomical lung resection.

Authors:  Henri Gondé; Constance Le Gac; André Gillibert; Benjamin Bottet; Marc Laurent; Matthieu Sarsam; Charles Hervouët; Rémi Varin; Jean-Marc Baste
Journal:  J Thorac Dis       Date:  2019-07       Impact factor: 2.895

View more