Literature DB >> 20541882

LC-determination of five paraben preservatives in saliva and toothpaste samples using UV detection and a short monolithic column.

Anastasia Zotou1, Ioanna Sakla, Paraskevas D Tzanavaras.   

Abstract

The present study reports the development and application of an HPLC-UV method for the simultaneous separation and determination of five paraben preservatives (methyl-, ethyl-, propyl-, n-butyl- and iso-butyl-paraben) in real samples. All analytes were separated efficiently in less than 20 min using a simple H(2)O:ACN linear gradient and a short monolithic column (50 mm x 4.6mm i.d.) at a flow rate of 3.0mL min(-1). Phenoxyethanol was used as chromatographic internal standard. The method was validated for linearity, limits of detection and quantification, accuracy and precision. Human saliva and toothpaste samples were analyzed after SPE pretreatment on Licrolut RP-18 cartridges. The detection limits varied between 0.1 and 0.3 mg L(-1) in all cases and the percent recoveries between 86 and 113%. Copyright (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20541882     DOI: 10.1016/j.jpba.2010.05.018

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

1.  Molybdenum disulfide-graphene oxide composites as dispersive solid-phase extraction adsorbents for the enrichment of four paraben preservatives in cosmetics.

Authors:  Wenjing Sun; Xiaoyu Hu; Xiaoyang Meng; Yuhong Xiang; Nengsheng Ye
Journal:  Mikrochim Acta       Date:  2021-07-15       Impact factor: 5.833

2.  Serum analysis in women and in vitro skin assay for the assessment of exposure to parabens in antiperspirants.

Authors:  Isarita Martins; Mayara Lambert; Ana Flávia Souza Pereira; Henrique Dipe de Faria; Elizabete Campos de Lima; Gislaine Ribeiro Pereira
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-11       Impact factor: 4.223

3.  Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector.

Authors:  Hazim Mohammed Ali; Ibrahim Hotan Alsohaimi; Mohammad Rizwan Khan; Mohammad Azam
Journal:  Pharmaceuticals (Basel)       Date:  2020-11-22

4.  Novel MIPs-Parabens based SPE Stationary Phases Characterization and Application.

Authors:  Angela Tartaglia; Abuzar Kabir; Songul Ulusoy; Halil Ibrahim Ulusoy; Giuseppe Maria Merone; Fabio Savini; Cristian D'Ovidio; Ugo de Grazia; Serena Gabrielli; Fabio Maroni; Pantaleone Bruni; Fausto Croce; Dora Melucci; Kenneth G Furton; Marcello Locatelli
Journal:  Molecules       Date:  2019-09-13       Impact factor: 4.411

  4 in total