Second-generation locking mechanisms and ethylene oxide sterilization reduce tibial insert backside damage in total knee arthroplasty.

Michael G Azzam1, Marcel E Roy, Leo A Whiteside.   

Abstract

This study evaluated the effects of polyethylene quality and locking mechanism on damage to the nonarticulating (backside) surface of retrieved tibial inserts in total knee arthroplasty. Inserts with peripheral capture (PC) locking mechanisms and ethylene oxide (EtO)-sterilized polyethylene were hypothesized to prevent major backside damage. A total of 156 inserts were sorted by locking mechanism and sterilization method and analyzed by damage scoring methods. Ninety-seven specimens exhibited burnishing. Significant positive linear correlations were observed between damage score and age in vivo for all combinations, but damage occurred at a significantly lower rate for second-generation PC implants with EtO sterilization. Most specimens in this group were undamaged (46/72), with others exhibiting only burnishing. Sex, body mass index, and weight did not influence backside damage.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20541356     DOI: 10.1016/j.arth.2010.04.024

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Changes in surface topography at the TKA backside articulation following in vivo service: a retrieval analysis.

Authors:  Richard J Holleyman; Susan C Scholes; David Weir; Simon S Jameson; Jim Holland; Tom J Joyce; David J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-07       Impact factor: 4.342

2.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

Review 3.  Towards an understanding of the painful total knee: what is the role of patient biology?

Authors:  Stephen Preston; Massimo Petrera; Christopher Kim; Michael G Zywiel; Rajiv Gandhi
Journal:  Curr Rev Musculoskelet Med       Date:  2016-12

4.  Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty.

Authors:  Łukasz Łapaj; Adrian Mróz; Paweł Kokoszka; Jacek Markuszewski; Justyna Wendland; Celina Helak-Łapaj; Jacek Kruczyński
Journal:  Acta Orthop       Date:  2016-10-26       Impact factor: 3.717

5.  Computational wear of knee implant polyethylene insert surface under continuous dynamic loading and posterior tibial slope variation based on cadaver experiments with comparative verification.

Authors:  Alaettin Ozer
Journal:  BMC Musculoskelet Disord       Date:  2022-09-19       Impact factor: 2.562

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.