Literature DB >> 20540841

Analysis of steam formation and migration in firefighters' protective clothing using X-ray radiography.

Corinne Keiser1, Peter Wyss, René M Rossi.   

Abstract

X-ray radiography was used to quantify evaporation and moisture transfer in a multilayer firefighter protective clothing system with defined wetted layers exposed to low thermal radiation. Evaporation was faster and took place at higher temperatures if the moisture was located in the outer layers of the clothing system. Moisture that evaporated in the outer layers of the clothing system was found to move inwards and condense in the inner layers and on the cap of the measurement cell. Results found in this study correlated well with the findings of our former study based on simple temperature distribution measurements to determine moisture transfer in protective clothing layers at low level thermal radiation.

Mesh:

Substances:

Year:  2010        PMID: 20540841     DOI: 10.1080/10803548.2010.11076839

Source DB:  PubMed          Journal:  Int J Occup Saf Ergon        ISSN: 1080-3548


  2 in total

1.  Prediction of Steam Burns Severity using Raman Spectroscopy on ex vivo Porcine Skin.

Authors:  Lina Zhai; Christian Adlhart; Fabrizio Spano; Riccardo Innocenti Malini; Agnieszka K Piątek; Jun Li; René M Rossi
Journal:  Sci Rep       Date:  2018-05-02       Impact factor: 4.379

Review 2.  Characterization and Modeling of Thermal Protective and Thermo-Physiological Comfort Performance of Polymeric Textile Materials-A Review.

Authors:  Sumit Mandal; Nur-Us-Shafa Mazumder; Robert J Agnew; Guowen Song; Rui Li
Journal:  Materials (Basel)       Date:  2021-05-05       Impact factor: 3.623