Literature DB >> 20538739

Diagnostic accuracy of modified transoesophageal echocardiography for pre-incision assessment of aortic atherosclerosis in cardiac surgery patients.

B van Zaane1, A P Nierich, G J Brandon Bravo Bruinsma, P M J Rosseel, F Z Ramjankhan, E E C de Waal, W F Buhre, K G M Moons.   

Abstract

BACKGROUND: Epiaortic ultrasound scanning (EUS) is regarded as the reference standard for detecting atherosclerosis in the ascending aorta (AA). Combined with appropriate surgical modifications, EUS use can significantly reduce the incidence of postoperative stroke when detecting severe AA atherosclerosis. A recently introduced modification of conventional transoesophageal echocardiography (TOE), known as the A-View method, has proven capable of inspecting the distal AA. The objective of this study was to quantify the diagnostic accuracy of modified TOE in assessing atherosclerosis of the distal AA.
METHODS: After approval by the institutional medical ethical committee and after obtaining written informed consent, 465 consecutive patients above 65 yr old, undergoing elective cardiac surgery with a median sternotomy, were included. The study followed a cross-sectional diagnostic design. All consecutive patients underwent modified TOE followed by EUS (reference standard) to assess the severity of distal AA atherosclerosis. We constructed contingency tables to compare the presence (and severity) of atherosclerosis, detected by the two techniques.
RESULTS: The positive predictive value of modified TOE for the detection of clinically significant atherosclerosis was 67%, and the negative predictive value was 97%. The sensitivity was 95% and the specificity was 79%. One patient suffered a pulmonary haemorrhage, although he recovered without further sequelae. We did not observe any clinical significant haemodynamic or ventilatory effects.
CONCLUSIONS: The high negative predictive value and sensitivity show that modified TOE yields adequate diagnostic accuracy for excluding clinically relevant aorta atherosclerosis without significant cardiopulmonary side-effects, provided that the A-View catheter is introduced carefully.

Entities:  

Mesh:

Year:  2010        PMID: 20538739     DOI: 10.1093/bja/aeq122

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  4 in total

Review 1.  Imaging Techniques for Diagnosis of Thoracic Aortic Atherosclerosis.

Authors:  Wouter W Jansen Klomp; George J Brandon Bravo Bruinsma; Arnoud W van 't Hof; Jan G Grandjean; Arno P Nierich
Journal:  Int J Vasc Med       Date:  2016-02-04

Review 2.  Modified transesophageal echocardiography of the dissected thoracic aorta; a novel diagnostic approach.

Authors:  Wouter W Jansen Klomp; Linda M Peelen; George J Brandon Bravo Bruinsma; Arnoud W J Van't Hof; Jan G Grandjean; Arno P Nierich
Journal:  Cardiovasc Ultrasound       Date:  2016-08-03       Impact factor: 2.062

3.  Impact of Modified Transesophageal Echocardiography on Mortality and Stroke after Cardiac Surgery: A Large Cohort Study.

Authors:  Wouter W Jansen Klomp; Carl G M Moons; Arno P Nierich; George J Brandon Bravo Bruinsma; Arnoud W J Van't Hof; Jan G Grandjean; Linda M Peelen
Journal:  Int J Vasc Med       Date:  2017-09-11

4.  From accuracy to patient outcome and cost-effectiveness evaluations of diagnostic tests and biomarkers: an exemplary modelling study.

Authors:  Hendrik Koffijberg; Bas van Zaane; Karel G M Moons
Journal:  BMC Med Res Methodol       Date:  2013-01-31       Impact factor: 4.615

  4 in total