Literature DB >> 20538351

Battery ingestion in children.

Tal Marom1, Abraham Goldfarb, Eyal Russo, Yehudah Roth.   

Abstract

INTRODUCTION: Ingestion of batteries by children became more frequent in recent years, due to the increasing accessibility of electronic toys and devices to children. Due to their electrochemical composition, impacted batteries in the esophagus may cause an extensive damage. Following the removal of a battery, the post-esophagoscopy management is still controversial. CASE
PRESENTATION: An otherwise healthy 8 year-old boy presented to the pediatric emergency room 3h after the unintentional swallowing of a lithium battery. On examination, the patient was diaphoretic and tachypneic. Plain PA chest film revealed a 2.5 cm diameter radiopaque round object in the upper esophagus. The patient was scheduled for an urgent rigid esophagoscopy which was performed 2h after admission. Esophagoscopy findings included an impacted lithium battery in an advanced emptying process at a level of 17 cm from the incisor teeth, with a 3rd degree ulcerative esophagitis. It was not possible to visualize either the distal esophagus or the stomach. A nasogastric tube was not inserted because of a significant risk for esophageal perforation if bluntly passed. Post-operative medical therapy included fasting, administration of intravenous antibiotic therapy, antacids, and steroids. Flexible esophagoscopy superior to the level of the mucosal injury performed one day later, revealed erosive esophagitis, without evidence of perforation. Upper digestive tract gastrografin swallow test performed 2 days after esophagoscopy did not demonstrate a leak from the esophagus, and oral feeding was carefully re-initiated. Treatment was discontinued the following day. Follow up on days 10 and 14 revealed a healthy child with normal swallowing. DISCUSSION: Battery ingestion-related injury results from direct pressure necrosis, local electrical currents and alkali leakage. Signs and symptoms of ingested battery are related to impaction duration, size of battery, battery content and peristaltic waves of the esophagus. Appropriate imaging studies should be performed to maximize identification of the foreign body before esophagoscopy. Esophageal stenting and adjuvant medical therapy (steroid therapy, antibiotic therapy and anti-reflux therapy) have a low evidence level of clinical benefit following caustic injuries from impacted batteries and spillage of their content to the esophagus. A judicious management should be tailored in each patient. Increased public and health personnel awareness is necessary to diminish the incidence of battery ingestion. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20538351     DOI: 10.1016/j.ijporl.2010.05.019

Source DB:  PubMed          Journal:  Int J Pediatr Otorhinolaryngol        ISSN: 0165-5876            Impact factor:   1.675


  12 in total

1.  Charon's Coins.

Authors:  Dominic Gascho; Simon Gentile; Stephan A Bolliger; Michael J Thali
Journal:  Forensic Sci Med Pathol       Date:  2016-07-18       Impact factor: 2.007

2.  Emergency care of esophageal foreign body impactions: timing, treatment modalities, and resource utilization.

Authors:  S D Crockett; S L W Sperry; C Brock Miller; N J Shaheen; E S Dellon
Journal:  Dis Esophagus       Date:  2012-03-27       Impact factor: 3.429

3.  Tracheoesophageal fistula following disc battery ingestion and foreign body impaction.

Authors:  Ahmad Khaleghnejad Tabari; Alireza Mirshemirani; Mohsen Rouzrokh; Javad Seyyedi; Nasibeh Khaleghnejad Tabari; Sajad Razavi; Mahshid Talebian
Journal:  Caspian J Intern Med       Date:  2011

4.  Spondylodiscitis associated with button battery ingestion: prompt evaluation with MRI.

Authors:  Allen Young; Aylin Tekes; Thierry A G M Huisman; Thangamadhan Bosemani
Journal:  Neuroradiol J       Date:  2015-10-12

5.  An unusual case of duodenal perforation caused by a lollipop stick: a case report.

Authors:  Eun Ae Cho; Du Hyeon Lee; Hyoung Ju Hong; Chang Hwan Park; Seon Young Park; Hyun Soo Kim; Sung Kyu Choi; Jong Sun Rew
Journal:  Clin Endosc       Date:  2014-03-31

6.  Multiple Gastric Erosion Early after a 3 V Lithium Battery (CR2025) Ingestion in an 18-Month-Old Male Patient: Consideration about the Proper Time of Intervention.

Authors:  Ioannis Patoulias; Christos Kaselas; Dimitrios Patoulias; Konstantinos Farmakis; Eleni Papacrivou; Maria Kalogirou; Thomas Feidantsis
Journal:  Case Rep Pediatr       Date:  2016-11-07

7.  Button battery foreign bodies in children: hazards, management, and recommendations.

Authors:  Mohammed Hossam Thabet; Waleed Mohamed Basha; Sherif Askar
Journal:  Biomed Res Int       Date:  2013-07-11       Impact factor: 3.411

8.  Ingested Foreign Bodies Removed by flexible Endoscopy in Pediatric Patients: A 10-year Retrospective Study [corrected].

Authors:  Seyed Ali Jafari; Maryam Khalesi; Simin Partovi; MohammadAli Kiani; Hamid Ahanchian; HamidReza Kianifar
Journal:  Iran J Otorhinolaryngol       Date:  2014-07

9.  Clinical evaluation of disc battery ingestion in children.

Authors:  AliReza Mirshemirani; Ahmad Khaleghnejad-Tabari; Jaefar Kouranloo; Naser Sadeghian; Mohsen Rouzrokh; Fatolah Roshanzamir; Sajad Razavi; Ali Akbar Sayary; Farid Imanzadeh
Journal:  Middle East J Dig Dis       Date:  2012-04

10.  Review of esophageal injuries and stenosis: Lessons learn and current concepts of management.

Authors:  Raghu Sampalli Ramareddy; Anand Alladi
Journal:  J Indian Assoc Pediatr Surg       Date:  2016 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.