| Literature DB >> 20538280 |
Liping Meng1, Shimin Wu, Fujun Ma, Ai Jia, Jianying Hu.
Abstract
A simple, fast and sensitive liquid chromatography-electrospray tandem mass spectrometry method was established for trace levels of nine haloacetic acids (HAAs) in drinking water. Water samples were removed of residual chlorine by adding L-ascorbic acid, and directly injected after filtered by 0.22 microm membrane. Nine HAAs were separated by liquid chromatography in 7.5 min, and the limits of detection were generally between 0.16 and 0.99 microg/L except for chlorodibromoacetic acid (1.44 microg/L) and tribromoacetic acid (8.87 microg/L). The mean recoveries of nine target compounds in spiked drinking water samples were 80.1-108%, and no apparent signal suppression was observed. Finally, this method was applied to determine HAAs in the tap water samples collected from five waterworks in Shandong, China. Nine HAAs except for monochloroacetic acid, monobromoacetic acid, dibromochloroacetic acid and tribromoacetic acid were detected, and the total concentrations were 7.79-36.5 microg/L. The determination results well met the first stage of the Disinfectants/Disinfection By-Products (D/DBP) Rules established by U.S.EPA and Guidelines for Drinking-water Quality of WHO. Crown Copyright 2010. Published by Elsevier B.V. All rights reserved.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20538280 DOI: 10.1016/j.chroma.2010.04.074
Source DB: PubMed Journal: J Chromatogr A ISSN: 0021-9673 Impact factor: 4.759