OBJECTIVE: The aim of this study was to investigate the long-term in vitro stability of soluble ST2 (sST2). DESIGN AND METHODS: EDTA plasma samples were drawn from 15 individuals with various diseases. The Presage ST2 assay was used for measurement of sST2 concentrations directly after blood collection and after storing plasma samples for 18 months at -20 degrees C and -80 degrees C. The default criterion for analyte stability was set at 95%. RESULTS: sST2 concentrations in the 15 individuals ranged from 12 U/mL to 140 U/mL. Directly after blood collection, the mean (+/-SD) sST2 concentration was 51+/-37 U/mL, and absolute analyte recoveries were 50+/-35 U/mL and 51+/-34 U/mL after storage of samples for 18 months at -20 degrees C and -80 degrees C, respectively. Relative analyte recoveries after 18 months of storage at -20 degrees C and -80 degrees C were 99+/-5% and 101+/-7%. CONCLUSION: sST2 is stable for at least 1.5 years in plasma samples stored at -20 degrees C and -80 degrees C. Copyright (c) 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
OBJECTIVE: The aim of this study was to investigate the long-term in vitro stability of soluble ST2 (sST2). DESIGN AND METHODS: EDTA plasma samples were drawn from 15 individuals with various diseases. The Presage ST2 assay was used for measurement of sST2 concentrations directly after blood collection and after storing plasma samples for 18 months at -20 degrees C and -80 degrees C. The default criterion for analyte stability was set at 95%. RESULTS: sST2 concentrations in the 15 individuals ranged from 12 U/mL to 140 U/mL. Directly after blood collection, the mean (+/-SD) sST2 concentration was 51+/-37 U/mL, and absolute analyte recoveries were 50+/-35 U/mL and 51+/-34 U/mL after storage of samples for 18 months at -20 degrees C and -80 degrees C, respectively. Relative analyte recoveries after 18 months of storage at -20 degrees C and -80 degrees C were 99+/-5% and 101+/-7%. CONCLUSION: sST2 is stable for at least 1.5 years in plasma samples stored at -20 degrees C and -80 degrees C. Copyright (c) 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Authors: Alexander R Opotowsky; Brittani Loukas; Christina Ellervik; Lilamarie E Moko; Michael N Singh; Elizabeth I Landzberg; Eric B Rimm; Michael J Landzberg Journal: World J Pediatr Congenit Heart Surg Date: 2016-11
Authors: Ravi H Parikh; Stephen L Seliger; Robert Christenson; John S Gottdiener; Bruce M Psaty; Christopher R deFilippi Journal: J Am Heart Assoc Date: 2016-08-01 Impact factor: 5.501
Authors: Zoe Wolcott; Ayush Batra; Matthew B Bevers; Cristina Sastre; Jane Khoury; Matthew Sperling; Brett C Meyer; Kyle B Walsh; Opeolu Adeoye; Joseph P Broderick; W Taylor Kimberly Journal: Ann Clin Transl Neurol Date: 2017-07-05 Impact factor: 4.511
Authors: Laurie W Geenen; Vivan J M Baggen; Annemien E van den Bosch; Jannet A Eindhoven; Judith A A E Cuypers; Maarten Witsenburg; Eric Boersma; Jolien W Roos-Hesselink Journal: Heart Date: 2019-01-30 Impact factor: 5.994
Authors: Shruti Rajesh Patel; Joerg Herrmann; Robert A Vierkant; Janet E Olson; Fergus J Couch; Antonious Hazim; Jeff A Sloan; Charles L Loprinzi; Kathryn J Ruddy Journal: J Clin Med Date: 2021-07-27 Impact factor: 4.241