Literature DB >> 20533627

Comparative in vivo study on the desensitizing efficacy of dentin desensitizers and one-bottle self-etching adhesives.

Xiaofen Yu1, Bing Liang, Xiaoting Jin, Baiping Fu, Matthias Hannig.   

Abstract

UNLABELLED: This in vivo study evaluated the desensitizing efficacy of two one-bottle self-etching adhesives, two dentin desensitizers and a placebo (water).
METHODS: Thirty-one volunteers with 55 hypersensitive teeth were recruited into this clinical investigation. The sensitive teeth were randomly assigned into five groups and treated with one of the following materials: iBond, Heraeus; Xeno V, Dentsply; Gluma desensitizer, Heraeus; Bifluorid 12, Voco; placebo (water). Mechanical and thermal stimuli were used to assess the tooth sensitivity response. Discomfort interval scale (DIS) scores of the sensitive teeth were recorded at three different investigation times (baseline, immediately and one month after treatment). Impressions were taken from the sensitive teeth at all three different investigation times, and replica models were made for the evaluation of the dentin surfaces by scanning electron microscopy. The Friedman test and the Mann Whitney U-test were used to analyze the data.
RESULTS: All dental materials significantly reduced the dentin hypersensitivity immediately (p < 0.05) and one month after treatment (p < 0.05), with the exception of Bifluorid 12 for mechanical tooth sensitivity. The placebo (water) only caused a short-term effect on the thermal dentin hypersensitivity (p < 0.05). Topical application of the dentin adhesives/desensitizers on sensitive dentinal areas resulted in occlusion of the patent tubules.
CONCLUSIONS: The one-bottle self-etching adhesives and dentin desensitizers involved in the current clinical investigation could significantly relieve dentin hypersensitivity immediately and over the course of a month after treatment (except for Bifluorid 12 for tooth mechanical sensitivity). The placebo (water) had an immediate effect on thermal dentin hypersensitivity.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20533627     DOI: 10.2341/09-346-C

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  6 in total

1.  Comparing the effect of a desensitizing material and a self-etch adhesive on dentin sensitivity after periodontal surgery: a randomized clinical trial.

Authors:  Hila Hajizadeh; Atefeh Nemati-Karimooy; Sara Majidinia; Amir Moeintaghavi; Marjaneh Ghavamnasiri
Journal:  Restor Dent Endod       Date:  2017-07-21

2.  Evaluation of Five Different Desensitizers: A Comparative Dentin Permeability and SEM Investigation In Vitro.

Authors:  Nasibe Aycan Yilmaz; Ertan Ertas; Hasan Orucoğlu
Journal:  Open Dent J       Date:  2017-01-31

3.  A randomized clinical trial of dentin hypersensitivity reduction over one month after a single topical application of comparable materials.

Authors:  Samar Hatem Abuzinadah; Abdulrahman Jafar Alhaddad
Journal:  Sci Rep       Date:  2021-03-24       Impact factor: 4.379

4.  Comparative Evaluation of the Effects of Diode Laser and Desensitizing Agents on the Treatment of Dentin Hypersensitivity: a Clinical Study.

Authors:  Mirjana Gojkov-Vukelic; Sanja Hadzic; Indira Mujic Jahic; Enes Pasic; Arma Muharemovic
Journal:  Acta Inform Med       Date:  2021-06

5.  Impact of Immediate Dentin Sealing Using Universal Adhesive under Simulated Pulp Pressure on Microtensile Bond Strength of Indirect Resin Composite Restorations and Dentin Permeability.

Authors:  Emad Abd Elfatah Abo-Alazm; Rehab Khalil Safy
Journal:  Eur J Dent       Date:  2021-11-16

6.  A comparative evaluation of the efficacy of two novel desensitising dentifrices.

Authors:  Ashley P Barlow; Jane He; Cindy Tian; Peter Jeffery; Stephen C Mason; Bao-Jun Tai; Han Jiang; Gareth D Rees; Min Quan Du
Journal:  Int J Dent       Date:  2012-12-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.