Renal artery embolization combined with radiofrequency ablation in a porcine kidney model: effect of small and narrowly calibrated microparticles as embolization material on coagulation diameter, volume, and shape.

C M Sommer1, N Kortes, S Zelzer, F U Arnegger, U Stampfl, N Bellemann, T Gehrig, F Nickel, H G Kenngott, C Mogler, T Longerich, H P Meinzer, G M Richter, H U Kauczor, B A Radeleff.   

Abstract

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume_segmented, and volume_calculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 ± 3.6 vs. 17.2 ± 1.8 mm; p < 0.001) and width (20.1 ± 2.9 vs. 12.6 ± 3.7 mm; p < 0.001); significantly larger volume_segmented (8.6 ± 3.2 vs. 3.0 ± 0.7 ml; p < 0.001) and volume_calculated (8.4 ± 3.0 ml vs. 3.3 ± 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 ± 0.10 vs. 1.48 ± 0.44; p < 0.05), sphericity (1.55 ± 0.44 vs. 1.96 ± 0.43; p < 0.01), and eccentricity (0.84 ± 0.61 vs. 1.73 ± 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 ± 0.14 vs. 0.45 ± 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.

Entities:  

Mesh:

Year:  2010        PMID: 20532774     DOI: 10.1007/s00270-010-9908-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

1.  Specific CT 3D rendering of the treatment zone after Irreversible Electroporation (IRE) in a pig liver model: the "Chebyshev Center Concept" to define the maximum treatable tumor size.

Authors:  Dominik Vollherbst; Stefan Fritz; Sascha Zelzer; Miguel F Wachter; Maya B Wolf; Ulrike Stampfl; Daniel Gnutzmann; Nadine Bellemann; Anne Schmitz; Jürgen Knapp; Philippe L Pereira; Hans U Kauczor; Jens Werner; Boris A Radeleff; Christof M Sommer
Journal:  BMC Med Imaging       Date:  2014-01-10       Impact factor: 1.930

2.  Creation of an ex-vivo bovine kidney flow model for testing embolic agents: work in progress.

Authors:  Luis Garza; Ryan Bitar; Barrett O'Donnell; Matthew Parker; Carlos Ortiz; Charles Hyman; John Walker; Ho-Young Song; Jorge Lopera
Journal:  CVIR Endovasc       Date:  2021-02-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.