Minimally invasive circumcision with a novel plastic clamp technique: a review of 7,500 cases.

Ferda M Senel1, Mustafa Demirelli, Sehmuz Oztek.   

Abstract

PURPOSE: We aimed to analyze the outcome of circumcisions performed with a new minimally invasive circumcision device.
METHODS: This is the first study, which reports the results of 7,500 children circumcised with minimally invasive technique utilizing a plastic clamp device (Ali's clamp) in our country. The results of this technique are compared to those of 5,700 children who underwent conventional circumcision.
RESULTS: The most common complication encountered after minimally invasive circumcision technique was found to be buried penis (1.04%). The second complication observed was infection (0.6%), which was significantly lower than the conventional group (p < 0.001). The third complication in plastic clamp group was bleeding with a rate of 0.4%. Bleeding was found to be the most common complication seen after conventional circumcision (5%) and was significantly higher than that of the plastic clamp group (p < 0.001). Total number of complications seen after plastic clamp technique was 2% when compared with 10.4% complication rate occurred after conventional circumcision (p < 0.001). The mean duration of circumcision time with plastic clamp technique was 4.5 +/- 1.5 min whereas with conventional circumcision it was 23 +/- 4 min (p < 0.0001).
CONCLUSION: Minimally invasive circumcision technique utilizing plastic clamp significantly reduced the complication rates. The cosmetic appearance after circumcisions performed with this technique was observed to be better than the conventional circumcisions. Due to reduced complications, as well as short duration and ease of application, the minimally invasive technique is suggested as the circumcision procedure of choice.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20532526     DOI: 10.1007/s00383-010-2632-3

Source DB:  PubMed          Journal:  Pediatr Surg Int        ISSN: 0179-0358            Impact factor:   1.827


  23 in total

Review 1.  Circumcision.

Authors:  Jack S Elder
Journal:  BJU Int       Date:  2007-06       Impact factor: 5.588

2.  Neonatal circumcision: a ten-year overview: with comparison of the Gomco clamp and the Plastibell device.

Authors:  W F Gee; J S Ansell
Journal:  Pediatrics       Date:  1976-12       Impact factor: 7.124

3.  Complication of a circumcision performed with a plastic bell clamp.

Authors:  R E Johnsonbaugh; B P Meyer; J D Catalano
Journal:  Am J Dis Child       Date:  1969-11

4.  Complications of circumcision.

Authors:  G W Kaplan
Journal:  Urol Clin North Am       Date:  1983-08       Impact factor: 2.241

Review 5.  Neonatal circumcision.

Authors:  S E Lerman; J C Liao
Journal:  Pediatr Clin North Am       Date:  2001-12       Impact factor: 3.278

6.  Male circumcision for HIV prevention in men in Rakai, Uganda: a randomised trial.

Authors:  Ronald H Gray; Godfrey Kigozi; David Serwadda; Frederick Makumbi; Stephen Watya; Fred Nalugoda; Noah Kiwanuka; Lawrence H Moulton; Mohammad A Chaudhary; Michael Z Chen; Nelson K Sewankambo; Fred Wabwire-Mangen; Melanie C Bacon; Carolyn F M Williams; Pius Opendi; Steven J Reynolds; Oliver Laeyendecker; Thomas C Quinn; Maria J Wawer
Journal:  Lancet       Date:  2007-02-24       Impact factor: 79.321

Review 7.  Circumcision for the prevention of urinary tract infection in boys: a systematic review of randomised trials and observational studies.

Authors:  D Singh-Grewal; J Macdessi; J Craig
Journal:  Arch Dis Child       Date:  2005-05-12       Impact factor: 3.791

8.  Complications of circumcision in Israel: a one year multicenter survey.

Authors:  Jacob Ben Chaim; Pinhas M Livne; Joseph Binyamini; Benyamin Hardak; David Ben-Meir; Yoram Mor
Journal:  Isr Med Assoc J       Date:  2005-06       Impact factor: 0.892

9.  Clinical application of a new device for minimally invasive circumcision.

Authors:  Yi-Feng Peng; Yue Cheng; Guo-Yao Wang; Suo-Qun Wang; Chao Jia; Ben-Hai Yang; Ru Zhu; Shu-Chuan Jian; Qing-Wen Li; Da-Wei Geng
Journal:  Asian J Androl       Date:  2008-05       Impact factor: 3.285

Review 10.  Complications of circumcision.

Authors:  N Williams; L Kapila
Journal:  Br J Surg       Date:  1993-10       Impact factor: 6.939

View more
  4 in total

1.  Examination of short and long term complications of thermocautery, plastic clamping, and surgical circumcision techniques.

Authors:  Ahmet Ali Tuncer; Elif Emel Ayar Erten
Journal:  Pak J Med Sci       Date:  2017 Nov-Dec       Impact factor: 1.088

2.  Safety and efficacy of a novel disposable circumcision device: a pilot randomized controlled clinical trial at 2 centers.

Authors:  Jingen Wang; Yongfei Zhou; Shuxia Xia; Zunwei Zhu; Linghua Jia; Yong Liu; Min Jiang
Journal:  Med Sci Monit       Date:  2014-03-20

Review 3.  Use of a disposable circumcision suture device versus conventional circumcision: a systematic review and meta-analysis.

Authors:  Zhong-Chao Huo; Gang Liu; Xiao-Yan Li; Fei Liu; Wen-Ju Fan; Ru-Hua Guan; Pei-Feng Li; De-Yang Mo; Yong-Zhi He
Journal:  Asian J Androl       Date:  2017 May-Jun       Impact factor: 3.285

4.  Circumcision with plastic Alisclamp technique in 4733 boys: our experiences to reduce complications

Authors:  Alev Süzen; Süleyman Cüneyt Karakuş; Nazile Ertürk
Journal:  Turk J Med Sci       Date:  2021-06-28       Impact factor: 0.973