Literature DB >> 20529176

Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone.

H Bilhan1, O Geckili, E Mumcu, E Bozdag, E Sünbüloğlu, O Kutay.   

Abstract

Achievement of primary stability during surgical placement of dental implants is one of the most important factors for successful osseointegration depending on various anatomical, surgical and implant-related factors. Resonance frequency analysis (RFA) has been shown as a non-invasive and objective technique for measuring the stability of implants. The aim of this study was to evaluate the effect of some surgical and implant-related factors in enhancing primary stability and to estimate a correlation between RFA and insertion torque (IT) in proximal regions of cow ribs representing cancellous bone. Fifteen implant beds were prepared in the most proximal region of six fresh cow ribs. Ninety implants with three different shapes and two different diameters were placed with two different surgical techniques, and the primary stability was compared using RFA and IT. Significantly higher RFA and IT values were achieved when under-dimensioned drilling was used as the surgical method (P<0·01); significantly higher IT values were obtained with the use of wider implants (P<0·01) and partially conical Astra Tech implants showed the highest IT values (P<0·01). When all the implants were considered, significant correlations between the IT and RFA values were noted (%40·6, P<0·05). Partially conical implants with a wide diameter to be placed with the modified surgical technique proposed appear to be useful in enhancing the primary stability in cancellous bone.
© 2010 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20529176     DOI: 10.1111/j.1365-2842.2010.02117.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  21 in total

1.  Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test.

Authors:  Dorjpalam Bayarchimeg; Hee Namgoong; Byung Kook Kim; Myung Duk Kim; Sungtae Kim; Tae-Il Kim; Yang Jo Seol; Yong Moo Lee; Young Ku; In-Chul Rhyu; Eun Hee Lee; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

2.  The effect of osseodensification on implant stability and bone density: A prospective observational study.

Authors:  Aseel R Hindi; Salwan Y Bede
Journal:  J Clin Exp Dent       Date:  2020-05-01

3.  The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis.

Authors:  Hamidreza Barikani; Shadab Rashtak; Soolmaz Akbari; Mohammadjavad Kharrazi Fard; Amirreza Rokn
Journal:  Dent Res J (Isfahan)       Date:  2014-01

4.  Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading.

Authors:  Seong-Beom Kim; Pil-Young Yun; Sang-Yun Kim; Yang-Jin Yi; Ji-Yun Kim; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

5.  Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis.

Authors:  Gorka Santamaría-Arrieta; Aritza Brizuela-Velasco; Felipe J Fernández-González; David Chávarri-Prado; Yelko Chento-Valiente; Eneko Solaberrieta; Markel Diéguez-Pereira; José-Antonio Vega; Jaime Yurrebaso-Asúa
Journal:  J Clin Exp Dent       Date:  2016-07-01

6.  In vitro comparison of primary stability of two implant designs in D3 bone.

Authors:  J González-Serrano; R Ortega-Aranegui; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01

7.  The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium.

Authors:  Omer Cohen; Dieter D Bosshardt; Evegeny Weinberg; Gil Slutzkey; Ofer Moses
Journal:  Materials (Basel)       Date:  2021-05-18       Impact factor: 3.623

8.  The effect of implant length and diameter on the primary stability in different bone types.

Authors:  Hamidreza Barikani; Shadab Rashtak; Soolmaz Akbari; Samareh Badri; Niloufar Daneshparvar; Amirreza Rokn
Journal:  J Dent (Tehran)       Date:  2013-09-30

9.  Effect of implant macro-design on primary stability: A prospective clinical study.

Authors:  Naroa Lozano-Carrascal; Oscar Salomó-Coll; Marta Gilabert-Cerdà; Nuria Farré-Pagés; Jordi Gargallo-Albiol; Federico Hernández-Alfaro
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-03-01

10.  Retrospective clinical study of ultrawide implants more than 6 mm in diameter.

Authors:  Jeong-Kui Ku; Yang-Jin Yi; Pil-Young Yun; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-08-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.