Literature DB >> 20524197

Effect of dentine smear layer on the performance of self-etching adhesive systems: A micro-tensile bond strength study.

Pisol Senawongse1, Anyarat Srihanon, Amara Muangmingsuk, Choltacha Harnirattisai.   

Abstract

This study aimed to evaluate the effect of the smear layer on the micro-tensile bond strength when two self-etching adhesives were used with different techniques. Flat dentine surfaces were prepared using either medium grit diamond burs or tungsten carbide burs. Ten specimens from each prepared surfaces were subjected for smear layer evaluation under SEM. Forty specimens from each of the prepared surfaces were further divided into two groups, bonded with either Clearfil SE Bond (SE) or Clearfil S(3) Bond (S3) using one of four applications (as manufacturer's instructions, agitation, reapplication, and increased application time), restored with composites and subjected to a micro-tensile bond strength test. Smear layers created with diamond burs were thicker than those created with tungsten carbide burs. Surfaces prepared with tungsten carbide burs produced a higher bond strength than those prepared with diamond burs and the same type of adhesive resin. SE demonstrated a higher bond strength than S3 for all surfaces. S3 applied with the agitation technique demonstrated a higher bond strength to dentine prepared with tungsten carbide and diamond burs than that applied with other techniques. SE applied with increased time on dentine treated with carbide burs produced the highest bond strength. In conclusion, a thick smear layer decreased bond strength to dentine, and this might be improved by modification of application technique. (c) 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20524197     DOI: 10.1002/jbm.b.31643

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

1.  Adhesive sonic agitation improves bonding durability to class-II cavity preparation.

Authors:  Mohamed M Awad; Feras Alhalabi; Mohamed Bamuqadm; Abdulmalik Alhoti; Abdulilah Almasaad; Ali Robiaan; Ahmed Almahdy; Ali Alrahlah; Mohammed H Ahmed
Journal:  Odontology       Date:  2022-09-29       Impact factor: 2.885

2.  Effect of rotary cutting instruments on the resin-tooth interfacial ultra structure: An in vivo study.

Authors:  Sudhir Sherawat; Sanjay Tewari; Jigyasa Duhan; Alpa Gupta; Rakesh Singla
Journal:  J Clin Exp Dent       Date:  2014-12-01

3.  Effect of the application time of phosphoric acid and self-etch adhesive systems to sclerotic dentin.

Authors:  Alexandra Patricia Mena-Serrano; Eugenio Jose Garcia; Miguel Muñoz Perez; Gislaine Cristine Martins; Rosa Helena Miranda Grande; Alessandro Dourado Loguercio; Alessandra Reis
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

  3 in total