OBJECTIVE: Glucose polymer-based emergency feeds (EF), used during illness to prevent metabolic decompensation and encephalopathy in inherited metabolic disorders, should be produced accurately and safely.
DESIGN: In a randomised, prospective, controlled study, the aim was to investigate if when preparing age-appropriate EF, a pre-measured sachet of glucose polymer, compared with scoops and weighing (using digital scales), decreased carer errors.
SUBJECTS: 47 carers (3 men, 44 women) of 52 inherited metabolic disorders patients were recruited. SETTING AND INTERVENTION: The carers made EF using all three techniques (weighing, scoops and pre-measured sachets) under supervision in controlled and home conditions. A 100-ml aliquot of each EF was analysed for carbohydrate concentration.
RESULTS: Under controlled preparation conditions, with 1 litre EFs, the % median glucose polymer concentration closest to target amounts was (1) pre-measured sachets (105%), (2) weighing (107%) and (3) scoops (118%; p<0.001). Similarly, under home conditions, the closest method was (1) pre-measured sachets (111%), (2) weighing (112%) and (3) scoops (118%; p<0.05). Under home preparation conditions, with 200 ml EFs, the pre-measured sachets were more likely to be within 20% of target weight than weighing (p<0.05), but there was no difference with scoops. Common errors observed were inaccurate water measurements (40% controlled and home conditions), incorrect scoop measurements and difficulty using digital scales. CONCLUSIONS; Overall, using pre-measured sachets was more accurate in EF production. Pre-measured sachets are likely to decrease preparation error and, therefore, reduce the risk of feed intolerance, particularly osmotic diarrhoea and consequential metabolic decompensation and encephalopathy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20522472     DOI: 10.1136/adc.2010.161711

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  2 in total

1.  Accuracy of formula preparation equipment for liquid measurement.

Authors:  Sharon Evans; Catherine Ashmore; Anne Daly; Anita MacDonald
Journal:  Mol Genet Metab Rep       Date:  2014-04-02

Review 2.  Proposed guidelines for the diagnosis and management of methylmalonic and propionic acidemia.

Authors:  Matthias R Baumgartner; Friederike Hörster; Carlo Dionisi-Vici; Goknur Haliloglu; Daniela Karall; Kimberly A Chapman; Martina Huemer; Michel Hochuli; Murielle Assoun; Diana Ballhausen; Alberto Burlina; Brian Fowler; Sarah C Grünert; Stephanie Grünewald; Tomas Honzik; Begoña Merinero; Celia Pérez-Cerdá; Sabine Scholl-Bürgi; Flemming Skovby; Frits Wijburg; Anita MacDonald; Diego Martinelli; Jörn Oliver Sass; Vassili Valayannopoulos; Anupam Chakrapani
Journal:  Orphanet J Rare Dis       Date:  2014-09-02       Impact factor: 4.123

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.