Factors such as high polymer dispersity and variation in elemental composition (of copolymers) often complicate the electrospray ionization mass spectrometry (ESI-MS) analysis of synthetic polymers with high molar mass. In the experiments described in this study, quaternary ammonium compounds were observed to facilitate the production of low charge state pseudomolecular ions when added to the spray solution for ESI-MS. This approach was then used for the ESI time-of-flight mass spectrometry (TOF-MS) analysis of synthetic polymers. Hexadecyltrimethylammonium chloride permitted the successful analysis of poly(ethylene glycol) of 2-40 kDa, poly(propylene glycol) and poly(tetramethylene glycol) oligomers. Increasing the quaternary ammonium compounds' concentration results in the production of low charge state pseudomolecular ions. A comparison of structurally different quaternary ammonium compounds showed that the best performance is expected from large molecules with specific charge localization, which leaves the charge available for interactions. The applicability of the method for the MS analysis of other polymeric systems was also studied. In the case of poly(tetramethylene glycol), the method not only shifted the distributions to higher m/z values but also allowed the detection of high molecular weight material that was not observed without addition of the modifier to the spray solution.

Entities:  

Year:  2010        PMID: 20521768     DOI: 10.1021/ac100769u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  The Competitive influence of Li+, Na+, K+, Ag+, and H+ on the fragmentation of a PEGylated polymeric excipient.

Authors:  Juan Wei; Anthony W T Bristow; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2014-10-18       Impact factor: 3.109

2.  Electrospray ionization tandem mass spectrometry of ammonium cationized polyethers.

Authors:  Andreas Nasioudis; Ron M A Heeren; Irene van Doormalen; Nicolette de Wijs-Rot; Oscar F van den Brink
Journal:  J Am Soc Mass Spectrom       Date:  2011-03-05       Impact factor: 3.109

3.  Hydrogen peroxide and sodium hypochlorite disinfectants are more effective against Staphylococcus aureus and Pseudomonas aeruginosa biofilms than quaternary ammonium compounds.

Authors:  Caitlinn B Lineback; Carine A Nkemngong; Sophie Tongyu Wu; Xiaobao Li; Peter J Teska; Haley F Oliver
Journal:  Antimicrob Resist Infect Control       Date:  2018-12-17       Impact factor: 4.887

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.