Literature DB >> 20519425

Global warming potential of inhaled anesthetics: application to clinical use.

Susan M Ryan1, Claus J Nielsen.   

Abstract

BACKGROUND: Inhaled anesthetics are recognized greenhouse gases. Calculating their relative impact during common clinical usage will allow comparison to each other and to carbon dioxide emissions in general.
METHODS: We determined infrared absorption cross-sections for sevoflurane and isoflurane. Twenty-year global warming potential (GWP(20)) values for desflurane, sevoflurane, and isoflurane were then calculated using the present and previously published infrared results, and best estimate atmospheric lifetimes were determined. The total quantity of each anesthetic used in 1 minimal alveolar concentration (MAC)-hour was then multiplied by the calculated GWP(20) for that anesthetic, and expressed as "carbon dioxide equivalent" (CDE(20)) in grams. Common fresh gas flows and carrier gases, both air/oxygen and nitrous oxide (N2O)/oxygen, were considered in the calculations to allow these examples to represent common clinical use of inhaled anesthetics.
RESULTS: GWP(20) values for the inhaled anesthetics were: sevoflurane 349, isoflurane 1401, and desflurane 3714. CDE(20) values for 1 MAC-hour at 2 L fresh gas flow were: sevoflurane 6980 g, isoflurane 15,551 g, and desflurane 187,186 g. Comparison among these anesthetics produced a ratio of sevoflurane 1, isoflurane 2.2, and desflurane 26.8. When 60% N2O/40% oxygen replaced air/oxygen as a carrier gas combination, and inhaled anesthetic delivery was adjusted to deliver 1 MAC-hour of anesthetic, sevoflurane CDE(20) values were 5.9 times higher with N2O than when carried with air/O2, isoflurane values were 2.9 times higher, and desflurane values were 0.4 times lower. On a 100-year time horizon with 60% N2O, the sevoflurane CDE(100) values were 19 times higher than when carried in air/O2, isoflurane values were 9 times higher, and desflurane values were equal with and without N2O.
CONCLUSIONS: Under comparable and common clinical conditions, desflurane has a greater potential impact on global warming than either isoflurane or sevoflurane. N2O alone produces a sizable greenhouse gas contribution relative to sevoflurane or isoflurane. Additionally, 60% N2O combined with potent inhaled anesthetics to deliver 1 MAC of anesthetic substantially increases the environmental impact of sevoflurane and isoflurane, and decreases that of desflurane. N2O is destructive to the ozone layer as well as possessing GWP; it continues to have impact over a longer timeframe, and may not be an environmentally sound tradeoff for desflurane. From our calculations, avoiding N2O and unnecessarily high fresh gas flow rates can reduce the environmental impact of inhaled anesthetics.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20519425     DOI: 10.1213/ANE.0b013e3181e058d7

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  31 in total

Review 1.  The energy burden and environmental impact of health services.

Authors:  Lawrence H Brown; Petra G Buettner; Deon V Canyon
Journal:  Am J Public Health       Date:  2012-10-18       Impact factor: 9.308

Review 2.  Environmental implications of anesthetic gases.

Authors:  Jeffrey S Yasny; Jennifer White
Journal:  Anesth Prog       Date:  2012

3.  New technology in anaesthesia: friend or foe?

Authors:  R Ross Kennedy
Journal:  J Clin Monit Comput       Date:  2014-04       Impact factor: 2.502

Review 4.  Waste anesthetic gas exposure and strategies for solution.

Authors:  Hai-Bo Deng; Feng-Xian Li; Ye-Hua Cai; Shi-Yuan Xu
Journal:  J Anesth       Date:  2018-02-05       Impact factor: 2.078

5.  The safety and efficacy of minimal-flow desflurane anesthesia during prolonged laparoscopic surgery.

Authors:  Sang Yoong Park; Chan Jong Chung; Jung Hoon Jang; Jae Young Bae; So Ron Choi
Journal:  Korean J Anesthesiol       Date:  2012-12-14

6.  Prospective validation of gas man simulations of sevoflurane in O2/air over a wide fresh gas flow range.

Authors:  Esther Candries; Andre M De Wolf; Jan F A Hendrickx
Journal:  J Clin Monit Comput       Date:  2022-03-22       Impact factor: 2.502

7.  The effect of nitrous oxide on the minimum alveolar concentration (MAC) and MAC derivatives of isoflurane in dogs.

Authors:  Debra A Voulgaris; Christine M Egger; M Reza Seddighi; Barton W Rohrbach; Lydia C Love; Thomas J Doherty
Journal:  Can J Vet Res       Date:  2013-04       Impact factor: 1.310

8.  Comparison of the Effects of Minimal and High-Flow Anaesthesia on Cerebral Perfusion During Septorhinoplasty.

Authors:  Leyla Kazancıoğlu; Şule Batçık; Başar Erdivanlı; Ahmet Şen; Engin Dursun
Journal:  Turk J Anaesthesiol Reanim       Date:  2019-02-01

9.  Reducing the oxygen concentration of gases delivered from anaesthetic machines unadapted for medical air.

Authors:  R E Clutton; G Schoeffmann; M Chesnil; R Gregson; F Reed; H Lawson; M Eddleston
Journal:  Vet Rec       Date:  2011-08-22       Impact factor: 2.695

10.  Risk Management Status of Waste Anesthetic Gases Using ECRI Institute Standards.

Authors:  S Asefzadeh; Ar Raeisi; A Mousavi
Journal:  Iran J Public Health       Date:  2012-11-01       Impact factor: 1.429

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.