Literature DB >> 20519193

Improved 'cut-down' technique for transvenous pacemaker lead implantation.

Theofilos M Kolettis1, Dimitrios N Lysitsas, Dimitrios Apostolidis, Giannis G Baltogiannis, Eleni Sourla, Lampros K Michalis.   

Abstract

AIMS: We improved the cut-down approach aiming at minimizing the subclavian/axillary vein puncture during implantation of permanent pacemaker leads. METHODS AND
RESULTS: We incorporated previously reported refinements of the cut-down approach, i.e. the use of a hydrophilic guidewire when direct lead insertion failed and cannulation of retro-pectoral veins in cases of insufficient calliper of the cephalic vein. In addition, we introduced two further techniques, namely the simultaneous use of two guidewires and the use of stiff angiography guidewires. The efficacy of this integrated 'no-puncture' strategy was assessed in the first consecutive 200 patients and was compared with the 'standard' approach in an equal number of consecutive preceding implantations. Puncture was required more often (P < 0.0001) in the 'standard'-approach group (40/200; 20.0%). The 'no-puncture' policy was successful in 192/200 (96%) of implantations over a course of 40 months with absence of major complications. This was due to more frequent (P < 0.0001) use of hydrophilic guidewires (49.0% vs. 9.5% of cases), as well as due to cannulation of retro-pectoral veins (3.5%), use of a second guidewire (16.0%) and use of stiff guidewires (7.0%).
CONCLUSION: The improved cut-down approach obviates subclavian/axillary puncture in the vast majority of cases and improves the safety of pacemaker implantation.

Entities:  

Mesh:

Year:  2010        PMID: 20519193     DOI: 10.1093/europace/euq173

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

1.  A novel technique for ligation of the cephalic vein reduces hemorrhaging during a two-in-one insertion of dual cardiac device leads.

Authors:  Takatsugu Kajiyama; Marehiko Ueda; Masayuki Ishimura; Naotaka Hashiguchi; Masahiro Nakano; Yusuke Kondo; Yoshio Kobayashi
Journal:  Indian Pacing Electrophysiol J       Date:  2018-04-13

2.  Scoring System Assessment of Cephalic Vein Access for Device Implantation.

Authors:  Jane Taleski; Lidija Poposka; Filip Janusevski; Bekim Pocesta; Vladimir Boskov; Noel G Boyle
Journal:  J Innov Card Rhythm Manag       Date:  2018-08-15

3.  Triple lead cephalic versus subclavian vein approach in cardiac resynchronization therapy device implantation.

Authors:  Julia Vogler; Anne Geisler; Nils Gosau; Samer Hakmi; Stephan Willems; Tienush Rassaf; Reza Wakili; Elif Kaya
Journal:  Sci Rep       Date:  2018-12-07       Impact factor: 4.379

4.  Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience.

Authors:  Bakhtawar Shah; Shahab Saidullah; Muhammad Aamer Niaz; Farrukh Zaman; Zahida Parveen; Aamir Ghazanfar; Hassan Mumtaz
Journal:  Cureus       Date:  2022-02-15
  4 in total