Literature DB >> 20515070

Investigations on the coupling of high-performance liquid chromatography to direct analysis in real time mass spectrometry.

Walter Eberherr1, Wolfgang Buchberger, Robert Hertsens, Christian W Klampfl.   

Abstract

A novel hyphenated technique namely the combination of HPLC with direct analysis in real time (DART) mass spectrometry (MS) is presented. The coupling of HPLC to DART-MS was achieved by a simple interface design with a capillary end piece transferring the HPLC effluent to the ionization region of the DART. Flow rates (0.3-1.6 mL min(-1)) and inner diameters of the capillary (50-150 microm) were harmonized to provide a stable liquid jet. Ionization-related parameters optimized included positioning of the capillary end piece with respect to He outlet of the ionization source and the MS inlet, He heater temperature and He flow rate. Among DART-MS voltages, the grid electrode voltage proved to have the most pronounced effect on signal intensities. A major benefit of this setup is the possibility to employ (commonly not MS-compatible) HPLC eluents such as phosphate buffers up to a phosphate concentration of 120 mM even at typical HPLC flow rates such as 1 mL min(-1) and above without negative side effects like contamination of the ion source or ion suppression. Experiments evaluating the correlation of signal intensity to mass-flow and concentration revealed that DART-MS can be seen as a mass flow sensitive detector. The usability of this hyphenated technique has been tested on the example of four parabenes (measured in the negative ion mode) as well as a set of pyrazine derivatives (measured in the positive ion mode). For the parabenes limits of detection (LOD) in the range of 20-55 microg L(-1) and linear ranges from at least 200-10000 microg L(-1) with correlation coefficients better than 0.997 were obtained.

Entities:  

Year:  2010        PMID: 20515070     DOI: 10.1021/ac1008496

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Signal and Charge Enhancement for Protein Analysis by Liquid Chromatography-Mass Spectrometry with Desorption Electrospray Ionization.

Authors:  Yan Liu; Zhixin Miao; Rajeswari Lakshmanan; Rachel R Ogorzalek Loo; Joseph A Loo; Hao Chen
Journal:  Int J Mass Spectrom       Date:  2012-07-01       Impact factor: 1.986

2.  Coupling of ultrafast LC with mass spectrometry by DESI.

Authors:  Yi Cai; Yong Liu; Roy Helmy; Hao Chen
Journal:  J Am Soc Mass Spectrom       Date:  2014-07-15       Impact factor: 3.109

3.  Mass spectrometric analysis of carisoprodol and meprobamate in rat brain microdialysates.

Authors:  Laszlo Prokai; Petr Fryčák; Vien Nguyen; Michael J Forster
Journal:  J Mass Spectrom       Date:  2016-10       Impact factor: 1.982

4.  A new splitting method for both analytical and preparative LC/MS.

Authors:  Yi Cai; Daniel Adams; Hao Chen
Journal:  J Am Soc Mass Spectrom       Date:  2013-11-20       Impact factor: 3.109

5.  Plasma-spray ionization (PLASI): a multimodal atmospheric pressure ion source for liquid stream analysis.

Authors:  Adam Kaylor; Prabha Dwivedi; Jennifer J Pittman; María Eugenia Monge; Guilong Cheng; Shelly Li; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2014-07-08       Impact factor: 3.109

6.  What Is the Opposite of Pandora's Box? Direct Analysis, Ambient Ionization, and a New Generation of Atmospheric Pressure Ion Sources.

Authors:  Robert B Cody
Journal:  Mass Spectrom (Tokyo)       Date:  2013-04-15
  6 in total