Literature DB >> 20515063

Evaluation of accurate mass and relative isotopic abundance measurements in the LTQ-orbitrap mass spectrometer for further metabolomics database building.

Ying Xu1, Jean-François Heilier, Geoffrey Madalinski, Eric Genin, Eric Ezan, Jean-Claude Tabet, Christophe Junot.   

Abstract

Recently, high-resolution mass spectrometry has been largely employed for compound identification, thanks to accurate mass measurements. As additional information, relative isotope abundance (RIA) is often needed to reduce the number of candidates prior to tandem MS(n). Here, we report on the evaluation of the LTQ-Orbitrap, in terms of accurate mass and RIA measurements for building further metabolomics spectral databases. Accurate mass measurements were achieved in the ppm range, using external calibration within 24 h, and remained at <5 ppm over a one-week period. The experimental relative abundances of (M+1) isotopic ions were evaluated in different data sets. First of all, 137 solutions of commercial compounds were analyzed by flow injection analysis in both the positive and negative ion modes. It was found that the ion abundance was the main factor impacting the accuracy of RIA measurements. It was possible to define some intensity thresholds above which errors were systematically <20% of their theoretical values. The same type of results were obtained with analyses from two biological media. Otherwise, no significant effect of ion transmission between the LTQ ion trap and the Orbitrap analyzer on RIA measurement errors was found, whereas the reliability of RIA measurements was dramatically improved by reducing the mass detection window. It was also observed that the signal integration method had a significant impact on RIA measurement errors, with the most-reliable results being obtained with peak height integrations. Finally, automatic integrations using the data preprocessing software XCMS and MZmine gave results similar to those obtained by manual integration, suggesting that it is relevant to use the RIA information in automatic elemental composition determination software from metabolomic peak tables.

Mesh:

Substances:

Year:  2010        PMID: 20515063     DOI: 10.1021/ac100271j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  23 in total

1.  Qualitative aspects and validation of a screening method for pesticides in vegetables and fruits based on liquid chromatography coupled to full scan high resolution (Orbitrap) mass spectrometry.

Authors:  Hans G J Mol; Paul Zomer; Maarten de Koning
Journal:  Anal Bioanal Chem       Date:  2012-06-05       Impact factor: 4.142

2.  Spectral accuracy and sulfur counting capabilities of the LTQ-FT-ICR and the LTQ-Orbitrap XL for small molecule analysis.

Authors:  Samantha L Blake; S Hunter Walker; David C Muddiman; David Hinks; Keith R Beck
Journal:  J Am Soc Mass Spectrom       Date:  2011-09-21       Impact factor: 3.109

Review 3.  Metabolomics: A Primer.

Authors:  Xiaojing Liu; Jason W Locasale
Journal:  Trends Biochem Sci       Date:  2017-02-11       Impact factor: 13.807

Review 4.  Mass spectrometry in chronic kidney disease research.

Authors:  Michael L Merchant
Journal:  Adv Chronic Kidney Dis       Date:  2010-11       Impact factor: 3.620

5.  Identification and Partial Structural Characterization of Mass Isolated Valsartan and Its Metabolite with Messenger Tagging Vibrational Spectroscopy.

Authors:  Olga Gorlova; Sean M Colvin; Antonio Brathwaite; Fabian S Menges; Stephanie M Craig; Scott J Miller; Mark A Johnson
Journal:  J Am Soc Mass Spectrom       Date:  2017-08-11       Impact factor: 3.109

6.  Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data.

Authors:  Bertrand Rochat
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-23       Impact factor: 3.109

7.  Mass accuracy and isotopic abundance measurements for HR-MS instrumentation: capabilities for non-targeted analyses.

Authors:  Ann M Knolhoff; John H Callahan; Timothy R Croley
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-12       Impact factor: 3.109

8.  Increasing the multiplexing capacity of TMTs using reporter ion isotopologues with isobaric masses.

Authors:  Graeme C McAlister; Edward L Huttlin; Wilhelm Haas; Lily Ting; Mark P Jedrychowski; John C Rogers; Karsten Kuhn; Ian Pike; Robert A Grothe; Justin D Blethrow; Steven P Gygi
Journal:  Anal Chem       Date:  2012-08-20       Impact factor: 6.986

9.  Direct infusion analysis of nucleotide mixtures of very similar or identical elemental composition.

Authors:  Ryan Quinn; Maria Basanta-Sanchez; Rebecca E Rose; Daniele Fabris
Journal:  J Mass Spectrom       Date:  2013-06       Impact factor: 1.982

10.  Accelerated turnover of MHC class II molecules in nonobese diabetic mice is developmentally and environmentally regulated in vivo and dispensable for autoimmunity.

Authors:  Alessandra De Riva; Mark C Varley; Leslie J Bluck; Anne Cooke; Michael J Deery; Robert Busch
Journal:  J Immunol       Date:  2013-05-15       Impact factor: 5.422

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.