Q Zhou1, Z J Ye, Y Su, J C Zhang, H Z Shi. 1. Department of Respiratory Diseases, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, PR China.
Abstract
BACKGROUND: N-terminal pro-brain natriuretic peptide (NT-proBNP) is a biomarker useful in diagnosis of pleural effusion due to heart failure. Thus far, its overall diagnostic accuracy has not been systematically reviewed. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of the measurement of pleural NT-proBNP for identifying pleural effusion due to heart failure. METHODS: After a systematic review of English-language studies, sensitivity, specificity, and other measures of accuracy of NT-proBNP concentrations in pleural fluid in the diagnosis of pleural effusion resulting from heart failure were pooled using fixed-effects models. Summary receiver operating characteristic curves were used to summarise overall test performance. RESULTS: Eight publications met the inclusion criteria. The summary estimates for pleural NT-proBNP in the diagnosis of pleural effusion attributable to heart failure were: sensitivity 0.95 (95% CI 0.92 to 0.97), specificity 0.94 (0.92 to 0.96), positive likelihood ratio 14.12 (10.23 to 19.51), negative likelihood ratio 0.06 (0.04 to 0.09) and diagnostic OR 213.87 (122.50 to 373.40). CONCLUSIONS: NT-proBNP levels in pleural fluid showed a high diagnostic accuracy and may help accurately differentiate cardiac from non-cardiac conditions in patients presenting with pleural effusion.
BACKGROUND: N-terminal pro-brain natriuretic peptide (NT-proBNP) is a biomarker useful in diagnosis of pleural effusion due to heart failure. Thus far, its overall diagnostic accuracy has not been systematically reviewed. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of the measurement of pleuralNT-proBNP for identifying pleural effusion due to heart failure. METHODS: After a systematic review of English-language studies, sensitivity, specificity, and other measures of accuracy of NT-proBNP concentrations in pleural fluid in the diagnosis of pleural effusion resulting from heart failure were pooled using fixed-effects models. Summary receiver operating characteristic curves were used to summarise overall test performance. RESULTS: Eight publications met the inclusion criteria. The summary estimates for pleuralNT-proBNP in the diagnosis of pleural effusion attributable to heart failure were: sensitivity 0.95 (95% CI 0.92 to 0.97), specificity 0.94 (0.92 to 0.96), positive likelihood ratio 14.12 (10.23 to 19.51), negative likelihood ratio 0.06 (0.04 to 0.09) and diagnostic OR 213.87 (122.50 to 373.40). CONCLUSIONS:NT-proBNP levels in pleural fluid showed a high diagnostic accuracy and may help accurately differentiate cardiac from non-cardiac conditions in patients presenting with pleural effusion.