Literature DB >> 20510899

Development of a robust ionic liquid-based dispersive liquid-liquid microextraction against high concentration of salt for preconcentration of trace metals in saline aqueous samples: application to the determination of Pb and Cd.

Seyed Reza Yousefi1, Farzaneh Shemirani.   

Abstract

A new ionic liquid-based dispersive liquid-liquid microextraction method was developed for preconcentration and determination of compounds in aqueous samples containing very high salt concentrations. This method can solve the problems associated with the limited application of the conventional IL-based DLLME in these samples. This is believed to arise from dissolving of the ionic liquids in aqueous samples with high salt content. In this method, the robustness of microextraction system against high salt concentration (up to 40%, w/v) is increased by introducing a common ion of the ionic liquid into the sample solution. The proposed method was applied satisfactorily to the preconcentration of lead and cadmium in saline samples. After preconcentration, the settled IL-phase was dissolved in 100 microL ethanol and aspirated into the flame atomic absorption spectrometer (FAAS) using a home-made microsample introduction system. Several variables affecting the microextraction efficiency were investigated and optimized. Under the optimized conditions and preconcentration of only 10 mL of sample, the enhancement factors of 273 and 311 and the detection limits of 0.6 microg L(-1) and 0.03 microg L(-1) were obtained for lead and cadmium, respectively. Validation of the method was performed by both an analysis of a certified reference material (CRM) and comparison of results with those obtained by ISO standard method. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Year:  2010        PMID: 20510899     DOI: 10.1016/j.aca.2010.04.026

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

Authors:  Sadaf S Arain; Tasneem G Kazi; Asma J Arain; Hassan I Afridi; Muhammad B Arain; Kapil D Brahman; Abdul H Panhwar; Mariam S Arain
Journal:  Environ Sci Pollut Res Int       Date:  2015-04-23       Impact factor: 4.223

2.  Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan.

Authors:  Sadaf Sadia Arain; Tasneem Gul Kazi; Hassan Imran Afridi; Kapil Dev Brahman; Sumaira Khan; Abdul Haleem Panhwar; Muhammad Afzal Kamboh; Jamil R Memon
Journal:  Environ Monit Assess       Date:  2015-05-01       Impact factor: 2.513

3.  Zwitterion-functionalized polymer microspheres as a sorbent for solid phase extraction of trace levels of V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II) prior to their determination by ICP-MS.

Authors:  Xiaoyu Jia; Dirong Gong; Junyi Zhao; Hongyun Ren; Jiani Wang; Xian Zhang
Journal:  Mikrochim Acta       Date:  2018-03-19       Impact factor: 5.833

4.  Development of a dispersive liquid-liquid microextraction technique for the extraction and spectrofluorimetric determination of fluoxetine in pharmaceutical formulations and human urine.

Authors:  Ahad Bavili Tabrizi; Ahmad Rezazadeh
Journal:  Adv Pharm Bull       Date:  2012-06-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.