Literature DB >> 20510593

Human movement onset detection from isometric force and torque measurements: a supervised pattern recognition approach.

Paolo Soda1, Stefano Mazzoleni, Giuseppe Cavallo, Eugenio Guglielmelli, Giulio Iannello.   

Abstract

OBJECTIVE: Recent research has successfully introduced the application of robotics and mechatronics to functional assessment and motor therapy. Measurements of movement initiation in isometric conditions are widely used in clinical rehabilitation and their importance in functional assessment has been demonstrated for specific parts of the human body. The determination of the voluntary movement initiation time, also referred to as onset time, represents a challenging issue since the time window characterizing the movement onset is of particular relevance for the understanding of recovery mechanisms after a neurological damage. Establishing it manually as well as a troublesome task may also introduce oversight errors and loss of information.
METHODS: The most commonly used methods for automatic onset time detection compare the raw signal, or some extracted measures such as its derivatives (i.e., velocity and acceleration) with a chosen threshold. However, they suffer from high variability and systematic errors because of the weakness of the signal, the abnormality of response profiles as well as the variability of movement initiation times among patients. In this paper, we introduce a technique to optimise onset detection according to each input signal. It is based on a classification system that enables us to establish which deterministic method provides the most accurate onset time on the basis of information directly derived from the raw signal.
RESULTS: The approach was tested on annotated force and torque datasets. Each dataset is constituted by 768 signals acquired from eight anatomical districts in 96 patients who carried out six tasks related to common daily activities. The results show that the proposed technique improves not only on the performance achieved by each of the deterministic methods, but also on that attained by a group of clinical experts.
CONCLUSIONS: The paper describes a classification system detecting the voluntary movement initiation time and adaptable to different signals. By using a set of features directly derived from raw data, we obtained promising results. Furthermore, although the technique has been developed within the scope of isometric force and torque signal analysis, it can be applied to other detection problems where several simple detectors are available. Copyright (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20510593     DOI: 10.1016/j.artmed.2010.04.008

Source DB:  PubMed          Journal:  Artif Intell Med        ISSN: 0933-3657            Impact factor:   5.326


  3 in total

1.  Prolonged infrapatellar tendon vibration does not influence quadriceps maximal or explosive isometric force production in man.

Authors:  Adam Fry; Jonathan P Folland
Journal:  Eur J Appl Physiol       Date:  2014-05-21       Impact factor: 3.078

2.  A new detection method for EMG activity monitoring.

Authors:  Hichem Bengacemi; Karim Abed-Meraim; Olivier Buttelli; Abdelaziz Ouldali; Ammar Mesloub
Journal:  Med Biol Eng Comput       Date:  2019-12-17       Impact factor: 2.602

Review 3.  Rate of force development: physiological and methodological considerations.

Authors:  Nicola A Maffiuletti; Per Aagaard; Anthony J Blazevich; Jonathan Folland; Neale Tillin; Jacques Duchateau
Journal:  Eur J Appl Physiol       Date:  2016-03-03       Impact factor: 3.078