Literature DB >> 2050938

Increased plasma endothelin-1 in the early hours of acute myocardial infarction.

D J Stewart1, G Kubac, K B Costello, P Cernacek.   

Abstract

Endothelin is a novel endothelium-derived vasoactive peptide with potent vasoconstrictor action in the coronary bed; however, its possible contribution to myocardial ischemia and infarction is not known. Plasma endothelin-1 concentration was measured with use of a radioimmunoassay in serial venous samples from 22 patients over a 72 h period after acute myocardial infarction (14 patients with uncomplicated infarction [group I] and 8 patients with hemodynamic or ischemic sequelae [group II]). Twenty-two normal subjects and seven patients with stable angina served as the control subjects. Endothelin-1 levels in patients with stable coronary disease were not different from those of normal subjects (0.62 +/- 0.56 and 0.76 +/- 0.38 pg/ml, respectively). In group I, plasma levels of endothelin-1 rose sharply after myocardial infarction, reaching a peak of 4.95 +/- 0.78 pg/ml at 6 h after the onset of chest pain (p less than 0.05 compared with values in control subjects) and returning rapidly toward the normal range by 24 h. Patients with complicated infarction (group II) demonstrated a similar rapid increase in plasma endothelin-1 to a peak value of 8.29 +/- 1.95 pg/ml; however, plasma endothelin-1 remained elevated in these patients, becoming significantly different from values in group I at 48 and 72 h. There was no correlation between peak increases in creatine kinase and peak endothelin-1 in either group, suggesting that the stimulus for elevation of endothelin-1 was not myocardial necrosis itself. Furthermore, left ventricular ejection fraction did not correlate with the increase in endothelin-1 in group I patients, whereas there was a significant inverse relation between ventricular function and plasma endothelin-1 in group II.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2050938     DOI: 10.1016/s0735-1097(10)80214-1

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  48 in total

Review 1.  Do endothelin receptor antagonists have an antiarrhythmic potential during acute myocardial infarction? Evidence from experimental studies.

Authors:  Dimitrios L Oikonomidis; Giannis G Baltogiannis; Theofilos M Kolettis
Journal:  J Interv Card Electrophysiol       Date:  2010-06-08       Impact factor: 1.900

Review 2.  Bosentan and the endothelin system in congestive heart failure.

Authors:  S H Ellahham; V Charlon; Z Abassi; K A Calis; W K Choucair
Journal:  Clin Cardiol       Date:  2000-11       Impact factor: 2.882

3.  Comparative effects of endothelin (ET-1) and U46619 on human saphenous vein and gastroepiploic artery, sources of human autologous grafts.

Authors:  D B McNamara; J T Light; R K Minkes; R M Saroyan; P Kvamme; N Rowe; W R Webb; L Fox; M D Kerstein; N L Mills
Journal:  Mol Cell Biochem       Date:  1992-11-04       Impact factor: 3.396

Review 4.  Therapeutic role of bosentan in hypertension: lessons from the model of perinephritic hypertension.

Authors:  J E Donckier
Journal:  Heart Fail Rev       Date:  2001-12       Impact factor: 4.214

5.  Two-year prognosis after acute coronary syndrome in younger patients: Association with feeling depressed in the prior year, and BDI-II score and Endothelin-1.

Authors:  Luba Yammine; Lorraine Frazier; Nikhil S Padhye; Jennifer E Sanner; Matthew M Burg
Journal:  J Psychosom Res       Date:  2017-05-23       Impact factor: 3.006

6.  Poster communications.

Authors: 
Journal:  Br J Pharmacol       Date:  1993-07       Impact factor: 8.739

7.  Does plasma endothelin during thrombolysis depend on infarct size? A pilot study.

Authors:  P Di Pasquale; S Paterna; G Parrinello; V Bucca; F Pipitone; G Tricoli; G Licata
Journal:  Cardiovasc Drugs Ther       Date:  1995-12       Impact factor: 3.727

8.  Plasma endothelin-1 concentrations in patients with retinal vein occlusions.

Authors:  A Iannaccone; C Letizia; S Pazzaglia; E M Vingolo; G Clemente; M R Pannarale
Journal:  Br J Ophthalmol       Date:  1998-05       Impact factor: 4.638

9.  Heart ischaemia-reperfusion induces local up-regulation of vasoconstrictor endothelin ETB receptors in rat coronary arteries downstream of occlusion.

Authors:  G F Skovsted; L S Kruse; R Larsen; A F Pedersen; S Trautner; M Sheykhzade; L Edvinsson
Journal:  Br J Pharmacol       Date:  2014-06       Impact factor: 8.739

Review 10.  New Targets in the Drug Treatment of Heart Failure.

Authors:  James A Iwaz; Elizabeth Lee; Hermineh Aramin; Danilo Romero; Navaid Iqbal; Matt Kawahara; Fatima Khusro; Brian Knight; Minal V Patel; Sumita Sharma; Alan S Maisel
Journal:  Drugs       Date:  2016-02       Impact factor: 9.546

View more