| Literature DB >> 20508791 |
Jeong Woo Lee1, Deokyu Kim, Hyun Ho Choi, Dong Chan Kim.
Abstract
BACKGROUND: This study evaluated the efficacy of a T-wave change after the IV administration of low dose epinephrine containing the test dose during spinal anesthesia.Entities:
Keywords: Electrocardiography; Epidural injection; Epinephrine; Lidocaine
Year: 2010 PMID: 20508791 PMCID: PMC2876855 DOI: 10.4097/kjae.2010.58.4.351
Source DB: PubMed Journal: Korean J Anesthesiol ISSN: 2005-6419
Demographic Data and the Level of Sensory Block
Values are mean ± SD or number. Values of cold test and pin-prick test are median (5th percentile, 95th percentile). Group S: received 3 ml of normal saline, group L: received 3 ml of 1.0% lidocaine, group E5: received 3 ml of 1.0% lidocaine with epinephrine 5 µg, group E10: received 3 ml of 1.0% lidocaine with epinephrine 10 µg.
Baseline Values before Simulated Test Dose and the Maximum Change after Simulated Test Dose
Values are mean ± SD. HR: heart rate, SBP: systolic blood pressure. Group S: received 3 ml of normal saline, group L: received 3 ml of 1.0% lidocaine, group E5: received 3 ml of 1.0% lidocaine with epinephrine 5 µg, group E10: received 3 ml of 1.0% lidocaine with epinephrine 10 µg. Baseline values were no significant differences among the groups. *P < 0.05 compare with baseline value, †P < 0.05 compare with group S and group L.
Fig. 1The changes of heart rate after simulated test dose intravenous administration. Values are mean ± SD. Group S: received 3 ml of normal saline, group L: received 3 ml of 1.0% lidocaine, group E5: received 3 ml of 1.0% lidocaine with epinephrine 5 µg, group E10: received 3 ml of 1.0% lidocaine with epinephrine 10 µg. *P < 0.05 compare with baseline values in the group E5, †P < 0.05 compare with baseline values in the group E10.
Fig. 2The changes of systolic blood pressure after simulated test dose intravenous administration. Values are mean ± SD. Group S: received 3 ml of normal saline, group L: received 3 ml of 1.0% lidocaine, group E5: received 3 ml of 1.0% lidocaine with epinephrine 5 µg, group E10: received 3 ml of 1.0% lidocaine with epinephrine 10 µg. *P < 0.05 compare with baseline values in the group E5, †P < 0.05 compare with baseline values in the group E10.
Fig. 3The percentage changes of T-wave amplitude after simulated test dose intravenous administration. Values are mean ± SD. Group S: received 3 ml of normal saline, group L: received 3 ml of 1.0% lidocaine, group E5: received 3 ml of 1.0% lidocaine with epinephrine 5 µg, group E10: received 3 ml of 1.0% lidocaine with epinephrine 10 µg. *P < 0.05 compare with baseline values in the group E5, †P < 0.05 compare with baseline values in the group E10.
Sensitivity, Specificity, and Positive and Negative Predictive Values Based on The Changes of Heart Rate, Systolic Blood Pressure, and T-wave Amplitude for Lidocaine Group
HR: heart rate, SBP: systolic blood pressure. Group E5: received 3 ml of 1.0% lidocaine with epinephrine 5 µg, group E10: received 3 ml of 1.0% lidocaine with epinephrine 10 µg.
Adverse Effects after Simulated Test Dose Intravenous Administration
Values are numbers of patient. CNS symptoms: dizziness, nervousness, and vacantness, C-V symptoms: palpitation, chest discomfort, and facial flushing. Group S: received 3 ml of normal saline, group L: received 3 ml of 1.0% lidocaine, group E5: received 3 ml of 1.0% lidocaine with epinephrine 5 µg, group E10: received 3 ml of 1.0% lidocaine with epinephrine 10 µg. *P < 0.05 compare with group S.