Abstract
BACKGROUND: To assess radiobiological restrictions and tolerance doses as well as other toxic effects derived from repeated applications of single-fraction high dose rate irradiation of small liver volumes in clinical practice.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20507615 PMCID: PMC2887889 DOI: 10.1186/1748-717X-5-44
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Figure 1Image-fusion: Contrast-enhanced computed tomography (CT) after CT-guided positioning of brachytherapy catheters (arrows) in a liver metastasis of a colorectal carcinoma, merged with the last magnetic resonance imaging of the liver acquired after all interventions (grey delineation). The hypointensity area shows the impairment of hepatocyte function in the left liver lobe.
Figure 2Image fusion of CT-data set with the accumulated 3-D dosimetry of three different irradiation sessions. (a) Contrast-enhanced CT after first (No.1) CT-guided positioning of brachytherapy catheters (long arrow) in metastases of a colorectal carcinoma. The short arrow shows the 3-D dosimetry of another lesion, irradiated in session No.2. (b) Contrast-enhanced CT after third intervention (No.3) in the same patient. The arrow shows the upper boundary of the 3-D dosimetry of the lesion irradiated in session No.2. Physical doses are shown in the colour map.
Figure 3Development of radiation injury of the liver after HDR brachytherapy: (a) Colorectal metastasis in liver segment IV (arrow), T1w-GRE 20 minutes after application of Gd-BOPTA. (b) Contrast-enhanced planning-CT and dosimetry after insertion of brachytherapy catheters (arrow) in the metastasis. The coloured lines indicate different isodoses. Applicated dose at the tumor margin was 20 Gy. (c) MRI after 3 months with a decreased uptake (arrow) of Gd-BOPTA around the irradiated and shrunken metastasis (T1w-GRE 20 minutes after application of Gd-BOPTA).
Figure 4Liver biopsy. Biopsy was performed to rule out a suspected local recurrence. Tissue had been exposed to approximately 20 Gy two months ago. Heterogenous congestion of the sinusoids with beginning atrophy of liver cells. Hematoxylin-eosin, original magnification: ȕ100.
The extent of the irradiation effects ("cumulative pseudolesion" in cm3) and calculated D90 (for α/β = 2 Gy) with respect to the minimal prescribed dose inside of the clinical target volume (CTV) in the different irradiation sessions.
| Pat. | Cum. Pseudo-lesion Volume (cm3) | Fractions (n) | Interval between inter-ventions (months) | Interval between first irradiation & last MRI (months) | Interval between last irradiation & last MRI (months) | Minimal prescribed dose inside CTV (Gy) | Liver Volume (cm3) | |
|---|---|---|---|---|---|---|---|---|
| 1 | 18.80 | 289 | 3 | 3/3 | 17 | 11 | 20/20/20 | 1960 |
| 2 | 16.20 | 327 | 2 | 7 | 14 | 7 | 25/15 | 2184 |
| 3 | 35.20 | 135 | 4 | 7/1/8 | 31 | 3 | 15/20/20/20 | 1123 |
| 4 | 25.30 | 172 | 3 | 4/3 | 18 | 11 | 20/20/15 | 1548 |
| 5 | 17.20 | 710 | 2 | 12 | 5 | 4 | 15/15 | 2077 |
| 6 | 25.15 | 381 | 2 | 13 | 13 | 12 | 15/20 | 1357 |
| 7 | 16.40 | 239 | 2 | 7 | 18 | 11 | 25/15 | 1847 |
| 8 | 14.35 | 803 | 2 | 6 | 13 | 7 | 15/20 | 1463 |
| 9 | 31.90 | 92 | 4 | 4/4/8 | 24 | 7 | 15/15/20/20 | 1424 |
| 10 | 23.65 | 425 | 2 | 14 | 18 | 4 | 20/15 | 2054 |
| 11 | 28.35 | 178 | 2 | 5 | 10 | 4 | 15/20 | 1662 |
| 12 | 21.64 | 668 | 3 | 4/6 | 16 | 6 | 20/15/20 | 2165 |
| 13 | 21.70 | 207 | 2 | 10 | 12 | 3 | 15/15 | 1439 |
| 14 | 15.90 | 529 | 3 | 1/5 | 9 | 4 | 15/15/15 | 1441 |
| 15 | 16.30 | 238 | 2 | 11 | 14 | 3 | 20/15 | 2025 |
| 16 | 21.75 | 244 | 3 | 1/7 | 10 | 3 | 20/20/15 | 1604 |
| 17 | 33.20 | 476 | 4 | 1/10/1 | 19 | 9 | 25/15/25/25 | 1951 |
| 18 | 20.55 | 227 | 2 | 1 | 5 | 4 | 20/20 | 1387 |
| 19 | 14.90 | 319 | 2 | 11 | 10 | 8 | 15/15 | 1428 |
| 20 | 29.60 | 75 | 2 | 9 | 12 | 3 | 20/20 | 1246 |
| Mean | 22.40 | 336.7 | 3 | 5 | 14 | 6 | 20 | 1669.16 |
The different time intervals between the interventions and the different time intervals between the interventions and acquisition of MRI examinations are shown.
Figure 5Based on the total 3D-D.
The D90 for impairment of hepatocyte function ("cumulative pseudolesion") calculated for different α/β-values (2, 3, 10, 20, 100).
| D90 (Gy) for impairment of hepatocyte function for different α/β-values | |||||
|---|---|---|---|---|---|
| Patient | α/β = 2 | α/β = 3 | α/β = 10 | α/β = 20 | α/β = 100 |
| 1 | 18.80 | 19.00 | 19.99 | 20.90 | 23.60 |
| 2 | 16.20 | 16.40 | 16.65 | 17.30 | 18.80 |
| 3 | 35.20 | 35.70 | 36.50 | 36.90 | 38.10 |
| 4 | 25.30 | 25.40 | 26.20 | 27.00 | 29.60 |
| 5 | 17.20 | 17.30 | 18.00 | 18.65 | 20.45 |
| 6 | 25.15 | 25.20 | 25.65 | 26.15 | 27.85 |
| 7 | 16.40 | 16.60 | 17.50 | 18.45 | 20.70 |
| 8 | 14.35 | 14.45 | 15.20 | 15.87 | 17.55 |
| 9 | 31.90 | 32.60 | 33.40 | 34.00 | 36.80 |
| 10 | 23.65 | 23.80 | 24.75 | 25.78 | 28.80 |
| 11 | 28.35 | 28.40 | 29.90 | 30.90 | 34.70 |
| 12 | 21.64 | 21.70 | 22.65 | 23.48 | 26.10 |
| 13 | 21.70 | 21.80 | 22.45 | 23.10 | 25.00 |
| 14 | 15.90 | 16.10 | 17.10 | 17.90 | 20.10 |
| 15 | 16.30 | 16.40 | 16.95 | 17.70 | 19.45 |
| 16 | 21.75 | 21.90 | 22.10 | 22.90 | 25.20 |
| 17 | 33.20 | 34.10 | 34.90 | 35.60 | 37.10 |
| 18 | 20.55 | 20.60 | 20.85 | 21.35 | 22.50 |
| 19 | 14.90 | 15.10 | 16.00 | 16.80 | 19.00 |
| 20 | 29.60 | 29.90 | 30.00 | 30.80 | 31.90 |
| Mean | 22.40 | 22.62 | 23.34 | 24.08 | 26.17 |
| Stand. deviation | 6.47 | 6.62 | 6.64 | 6.61 | 6.68 |
Figure 6Mean D. Statistically there was a significant difference in the D90 results but the differences for clinical α/β-values were less than 1 Gy and therefore of no clinical. The star (*) represents one outlier in the series of calculation.
D90 (for α/β = 2) tested against various variables for correlation analysis.
| PEARSON CORRELATION | D90 (α/β = 2) |
|---|---|
| Interventions (n) | p = 0.004 |
| Cumulative Pseudolesion (cm3) | p = 0.037 |
| Interval: first irradiation - MRT (months) | p = 0.005 |
| Interval: last irradiation - MRT (months) | p = 0.745 |
| Mean interval between several interventions (ΣT/n) | p = 0.092 |
The D90 (for α/β = 2) correlated significantly positive with the number of interventions and the interval between the first irradiation and the last MRI (p < 0.05). There was a significant negative correlation between the D90 (for α/β = 2) and the volume of the cumulative pseudolesion (p = 0,037). There was a trend for a positive correlation (p = 0.092) between the D90 (for α/β = 2) and the mean interval between several interventions (ΣT/n).
The comparison between the two groups of different cumulative pseudolesion volumes (≤200 mL; >200 mL) showed a statistically significant difference in the D90 (α/β = 2).
| Critical irradiation volume | D90 (α/β = 2) |
|---|---|
| Cum. Pseudolesion ≤200 mL (n = 5) | 30.1 Gy |
| Cum. Pseudolesion >200 mL (n = 15) | 19.1 Gy |
| t-test | p = 0.01 |
The statistically significant level was set at p-value ≤ 0.05.