Literature DB >> 20495240

Upper airway detection and visualization from cone beam image slices.

Mehmet Celenk1, Mike L Farrell, Haluk Eren, K Kumar, G Dave Singh, Scott Lozanoff.   

Abstract

This paper describes a method developed to assist in the detection and reconstruction of a three dimensional (3D) model of the human upper airway using cone beam computed tomography (CBCT) image slices and a 3D Gaussian smoothing kernel. The segmented and reconstructed volumetric airway is characterized by the corresponding three principal axes that are selected for viewing direction orientation via rotation and translation. These axes are derived using the 3D Principal Component Analysis (PCA) result of the rendered volume. To finely adjust the view and access airway, the major and minor axes of each slice are also computed using the two dimensional (2D) PCA in the respective planes. The exterior volume view is visualized in two modes, namely, a solid surface (volume details transparent to user) view and a nontransparent (volume detail accessible) view. This functionality provides an application driven use of the 3D airway in CBCT based anatomy studies. The extracted information may be useful as an imaging biomarker in the diagnostic assessment of patients with upper airway respiratory conditions such as obstructive sleep apnea, allergic rhinitis, and other related diseases; as well as planning orthopedic/orthodontic therapies.

Entities:  

Mesh:

Year:  2010        PMID: 20495240     DOI: 10.3233/XST-2010-0248

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  5 in total

Review 1.  Three-dimensional segmentation of the upper airway using cone beam CT: a systematic review.

Authors:  N A Alsufyani; C Flores-Mir; P W Major
Journal:  Dentomaxillofac Radiol       Date:  2012-05       Impact factor: 2.419

2.  Automatic segmentation of the nasal cavity and paranasal sinuses from cone-beam CT images.

Authors:  Nhat Linh Bui; Sim Heng Ong; Kelvin Weng Chiong Foong
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-12-12       Impact factor: 2.924

3.  Cone beam computed tomography of plastinated hearts for instruction of radiological anatomy.

Authors:  Chih-Wei Chang; Gregory Atkinson; Niket Gandhi; Michael L Farrell; Steven Labrash; Alice B Smith; Neil S Norton; Takashi Matsui; Scott Lozanoff
Journal:  Surg Radiol Anat       Date:  2016-02-23       Impact factor: 1.246

Review 4.  The use of magnetic resonance imaging in the evaluation of upper airway structures in paediatric obstructive sleep apnoea syndrome: a systematic review and meta-analysis.

Authors:  Romeo Patini; Mariantonietta Arrica; Enrico Di Stasio; Patrizia Gallenzi; Massimo Cordaro
Journal:  Dentomaxillofac Radiol       Date:  2016-08-19       Impact factor: 2.419

5.  Three-dimensional airway evaluation in 387 subjects from one university orthodontic clinic using cone beam computed tomography.

Authors:  Chuen Chie Chiang; Meghan N Jeffres; Arthur Miller; David C Hatcher
Journal:  Angle Orthod       Date:  2012-06-04       Impact factor: 2.079

  5 in total