Literature DB >> 20491804

Determining corneal power using Pentacam after myopic photorefractive keratectomy.

Khalil Ghasemi Falavarjani1, Masih Hashemi, Mahmoud Joshaghani, Pejvak Azadi, Mohammad J Ghaempanah, Gholam H Aghai.   

Abstract

PURPOSE: To assess the accuracy of Pentacam Scheimpflug camera for corneal power measurement in eyes with previous photorefractive keratectomy for myopia.
METHODS: In this comparative interventional case series, 35 eyes of 35 patients who had myopic photorefractive keratectomy were studied. Corneal power was measured by conventional topography and Pentacam Scheimpflug camera, and equivalent keratometry readings (EKR) in different central corneal rings (0.5 to 4.5 mm), true net power and simulated keratometry (K) measurements as well as those obtained using Shammas no-history, Koch-Maloney and Haigis methods were compared with clinical history method.
RESULTS: All corneal power measurements except for the topography simulated K and true net power values were statistically similar to the clinical history values. Simulated keratometry and 4.5-mm EKR values were more closely correlated with clinical history method. Shammas formula, Pentacam simulated K and 3-, 4- and 4.5-mm EKR provided a 95% confidence interval within +/-0.50 D of the mean clinical history method value, among these, the width of the 95% limits of agreement (LoA) was narrower for Shammas and Pentacam simulated K and 4.5-mm EKR values; however, considerably large 95% LoA were found between each of these values and those obtained with the clinical history method. Estimated preoperative keratometry was statistically similar to the preoperative measurement; however, estimated refractive change was different from actual value.
CONCLUSIONS: The Pentacam 4.5-mm EKR and simulated keratometry may be used as an alternative to clinical history method to predict corneal power when pre-keratorefractive surgery data are unavailable; however, wide LoA should be considered in the calculations.

Entities:  

Mesh:

Year:  2010        PMID: 20491804     DOI: 10.1111/j.1442-9071.2010.02286.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  10 in total

1.  Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes.

Authors:  Yanjun Hua; Chao Pan; Qinmei Wang
Journal:  Int Ophthalmol       Date:  2019-03-01       Impact factor: 2.031

2.  Corneal power measurement with a new aberrometer/corneal topographer in eyes after small incision lenticule extraction for myopia.

Authors:  Chao Pan; Weina Tan; Yanjun Hua; Xiaohua Lei
Journal:  Int Ophthalmol       Date:  2019-05-27       Impact factor: 2.031

3.  Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.

Authors:  Kaevalin Lekhanont; Manachai Nonpassopon; Khemruetai Wannarosapark; Varintorn Chuckpaiwong
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

4.  Keratometric index obtained by Fourier-domain optical coherence tomography.

Authors:  Yanjun Hua; Aleksander Stojanovic; Tor Paaske Utheim; Xiangjun Chen; Sten Ræder; Jinhai Huang; Qinmei Wang
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

5.  Precision (Repeatability and Reproducibility) and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace.

Authors:  Yanjun Hua; Zequan Xu; Wei Qiu; Qiang Wu
Journal:  PLoS One       Date:  2016-01-11       Impact factor: 3.240

6.  Comparison of Corneal Power and Astigmatism between Simulated Keratometry, True Net Power, and Total Corneal Refractive Power before and after SMILE Surgery.

Authors:  Yishan Qian; Yan Liu; Xingtao Zhou; Rajeev Krishnan Naidu
Journal:  J Ophthalmol       Date:  2017-03-22       Impact factor: 1.909

7.  Comprehensive evaluation of total corneal refractive power by ray tracing in predicting corneal power in eyes after small incision lenticule extraction.

Authors:  Chao Pan; Weina Tan; Yanjun Hua; Xiaohua Lei
Journal:  PLoS One       Date:  2019-06-06       Impact factor: 3.240

8.  An Analysis of Scheimpflug Holladay-Equivalent Keratometry Readings Following Corneal Collagen Cross-Linking.

Authors:  Ayhan Saglik; Hakim Celik; Mustafa Aksoy
Journal:  Beyoglu Eye J       Date:  2019-08-08

9.  Comparing Standard Keratometry and Total Keratometry Before and After Myopic Corneal Refractive Surgery With a Swept-Source OCT Biometer.

Authors:  Ziyang Wang; Yanzheng Song; Wenli Yang; Dongjun Li; Wei Chen; Qi Zhao; Qian Liu; Changbin Zhai
Journal:  Front Med (Lausanne)       Date:  2022-07-12

10.  Evaluation of Equivalent Keratometry Readings Obtained by Pentacam HR (High Resolution).

Authors:  Yanjun Hua; Xiaolan Zhang; Tor Paaske Utheim; Jinhai Huang; Chao Pan; Weina Tan; Qinmei Wang
Journal:  PLoS One       Date:  2016-03-07       Impact factor: 3.240

  10 in total