| Literature DB >> 20490250 |
Florence de la Barrière1, Guillaume Druart, Nicolas Guérineau, Jean Taboury, Jérôme Primot, Joël Deschamps.
Abstract
We present a new method to measure the modulation transfer function (MTF) beyond the Nyquist frequency of a multichannel imaging system for which all the channels have parallel optical axes. Such a multichannel optical system produces a set of undersampled subimages. If the subimages contain nonredundant information, high spatial frequencies are folded between low spatial frequencies, leading to the possible extraction of frequencies higher than the Nyquist frequency. The measurement of the MTF of the multichannel system leads to the estimation of the resolution enhancement of the final image that can be obtained by applying a postprocessing algorithm to the collection of undersampled subimages. Experimental images are presented to validate this method.Year: 2010 PMID: 20490250 DOI: 10.1364/AO.49.002879
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980