Literature DB >> 20488777

Optimization of the table speed of lower extremity CT angiography protocols in different patient age groups.

Thanongchai Siriapisith1, Jitladda Wasinrat, Pramook Mutirangura, Chanean Ruangsetakit, Chumpol Wongwanit.   

Abstract

BACKGROUND: Scanning with 64-slice multidetector row CT (MDCT) is usually faster than blood flow in peripheral arteries of the lower extremities, and the distal arteries of lower extremities are difficult to visualize, particularly in elderly patients. Thus, the optimal table speed for CT angiography (CTA) studies should be adjusted for appropriate patient age groups.
OBJECTIVE: We evaluated the relative efficacy of different table speeds in several age groups of patients with suspected peripheral arterial occlusive disease (PAOD) undergoing CTA of lower extremity arteries, as a guideline for routine use.
METHODS: This retrospective study reviewed routine CTA of the lower extremity arteries of 107 patients with suspected PAOD to evaluate vascular opacification in each vascular segment of 5 age groups: < or =40 years (group 1), 41-60 years (group 2), 61-70 years (group 3), 71-75 years (group 4), and > or =76 years (group 5). Adequate vascular opacification was measured for attenuation in the suprarenal and infrarenal abdominal aorta and in the arteries of the lower extremity. Venous contamination was also measured.
RESULTS: Adequate vascular opacification from the suprarenal aorta to the level of the mid-popliteal artery was shown in all patients. Arterial opacification at the dorsalis pedis or plantar arteries was visualized in 85.7%-91.7% of patients and at the plantar arch arteries in 84.1%-91.7%. Minimal venous contamination was also shown adjacent to arterial enhancement, ranging from 0% to 28.6%.
CONCLUSION: Performing CTA of the lower extremities with 64-slice MDCT could reduce the table speed to allow adequate arterial opacification and minimal venous contamination. Copyright 2010 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20488777     DOI: 10.1016/j.jcct.2010.03.011

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  3 in total

1.  Improved aortic enhancement in CT angiography using slope-based triggering with table speed optimization: a pilot study.

Authors:  Mustafa R Bashir; Paul W Weber; Daniela B Husarik; Laurens E Howle; Rendon C Nelson
Journal:  Int J Cardiovasc Imaging       Date:  2011-09-07       Impact factor: 2.357

2.  Optimal table feed in run-off CT angiography in patients with abdominal aortic aneurysms.

Authors:  T Werncke; C von Falck; M Wittmann; T Elgeti; F K Wacker; B C Meyer
Journal:  Eur Radiol       Date:  2013-05-19       Impact factor: 5.315

3.  Diagnostic confidence of run-off CT-angiography as the primary diagnostic imaging modality in patients presenting with acute or chronic peripheral arterial disease.

Authors:  Thomas Werncke; Kristina Imeen Ringe; Christian von Falck; Martin Kruschewski; Frank Wacker; Bernhard Christian Meyer
Journal:  PLoS One       Date:  2015-04-02       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.