Literature DB >> 20482292

Polish sentence matrix test for speech intelligibility measurement in noise.

Edward Ozimek1, Anna Warzybok, Dariusz Kutzner.   

Abstract

The purpose of this study was to develop the Polish sentence matrix test (PSMT) to measure intelligibility of speech presented against a background noise. The PSMT consists of five columns containing: 10 names, 10 verbs, 10 numerals, 10 adjectives, and 10 nouns. Since each word was available as a separate sound file, it was possible to generate different sentences by juxtaposing randomly selected words taken from respective columns. This approach allows 100,000 unique sentences of a fixed grammatical structure to be generated. The speech reception threshold (SRT), i.e. the signal-to-noise ratio (SNR) providing 50% speech intelligibility and S(50), the slope of an intelligibility function at the SRT point, were shown to be -9.6 dB and 17.1 %/dB, respectively. Note that in this study dB is regarded as dB SNR, otherwise reference is given. PSMT was also evaluated using an adaptive 1-up/1-down staircase procedure in investigations with and without participation of an experimenter. No significant differences were shown for SRTs obtained in these investigations.

Mesh:

Year:  2010        PMID: 20482292     DOI: 10.3109/14992021003681030

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  14 in total

1.  The development and validation of the Closed-set Mandarin Sentence (CMS) test.

Authors:  Duo-Duo Tao; Qian-Jie Fu; John J Galvin; Ya-Feng Yu
Journal:  Speech Commun       Date:  2017-06-30       Impact factor: 2.017

2.  Cochlear implantation with hearing preservation yields significant benefit for speech recognition in complex listening environments.

Authors:  René H Gifford; Michael F Dorman; Henryk Skarzynski; Artur Lorens; Marek Polak; Colin L W Driscoll; Peter Roland; Craig A Buchman
Journal:  Ear Hear       Date:  2013 Jul-Aug       Impact factor: 3.570

3.  Implantation of the Bonebridge BCI 602 after Mastoid Obliteration with S53P4 Bioactive Glass: A Safe Method of Treating Difficult Anatomical Conditions-Preliminary Results.

Authors:  Bartłomiej Król; Katarzyna Beata Cywka; Magdalena Beata Skarżyńska; Piotr Henryk Skarżyński
Journal:  Life (Basel)       Date:  2021-04-22

4.  An eye-tracking paradigm for analyzing the processing time of sentences with different linguistic complexities.

Authors:  Dorothea Wendt; Thomas Brand; Birger Kollmeier
Journal:  PLoS One       Date:  2014-06-20       Impact factor: 3.240

Review 5.  Variations in the slope of the psychometric functions for speech intelligibility: a systematic survey.

Authors:  Alexandra MacPherson; Michael A Akeroyd
Journal:  Trends Hear       Date:  2014-06-06       Impact factor: 3.293

6.  Optimization of the Dutch matrix test by random selection of sentences from a preselected subset.

Authors:  Rolph Houben; Wouter A Dreschler
Journal:  Trends Hear       Date:  2015-05-11       Impact factor: 3.293

7.  The Principle of Inverse Effectiveness in Audiovisual Speech Perception.

Authors:  Luuk P H van de Rijt; Anja Roye; Emmanuel A M Mylanus; A John van Opstal; Marc M van Wanrooij
Journal:  Front Hum Neurosci       Date:  2019-09-26       Impact factor: 3.169

8.  A Comparative Study of a Novel Adhesive Bone Conduction Device and Conventional Treatment Options for Conductive Hearing Loss.

Authors:  Piotr H Skarzynski; Anna Ratuszniak; Kamila Osinska; Magdalena Koziel; Bartlomiej Krol; Katarzyna B Cywka; Henryk Skarzynski
Journal:  Otol Neurotol       Date:  2019-08       Impact factor: 2.311

9.  Methods of improving speech intelligibility for listeners with hearing resolution deficit.

Authors:  Adam Kupryjanow; Andrzej Czyzewski
Journal:  Diagn Pathol       Date:  2012-09-25       Impact factor: 2.644

10.  Speech Intelligibility of Cochlear-Implanted and Normal-Hearing Children.

Authors:  Sara Poursoroush; Ali Ghorbani; Zahra Soleymani; Mohammd Kamali; Negin Yousefi; Zahra Poursoroush
Journal:  Iran J Otorhinolaryngol       Date:  2015-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.