Literature DB >> 20479849

Cross-validation of interferometric synthetic aperture microscopy and optical coherence tomography.

Tyler S Ralston1, Steven G Adie, Daniel L Marks, Stephen A Boppart, P Scott Carney.   

Abstract

Computationally reconstructed interferometric synthetic aperture microscopy is coregistered with optical coherence tomography (OCT) focal plane data to provide quantitative cross validation with OCT. This is accomplished through a qualitative comparison of images and a quantitative analysis of the width of the point-spread function in simulation and experiment. The width of the ISAM point-spread function is seen to be independent of depth, in contrast to OCT.

Entities:  

Mesh:

Year:  2010        PMID: 20479849      PMCID: PMC3699328          DOI: 10.1364/OL.35.001683

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  14 in total

1.  Inverse scattering for optical coherence tomography.

Authors:  Tyler S Ralston; Daniel L Marks; P Scott Carney; Stephen A Boppart
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-05       Impact factor: 2.129

2.  Extended focus depth for Fourier domain optical coherence microscopy.

Authors:  R A Leitgeb; M Villiger; A H Bachmann; L Steinmann; T Lasser
Journal:  Opt Lett       Date:  2006-08-15       Impact factor: 3.776

3.  Inverse scattering for high-resolution interferometric microscopy.

Authors:  Tyler S Ralston; Daniel L Marks; Stephen A Boppart; P Scott Carney
Journal:  Opt Lett       Date:  2006-12-15       Impact factor: 3.776

4.  Inverse scattering for frequency-scanned full-field optical coherence tomography.

Authors:  Daniel L Marks; Tyler S Ralston; Stephen A Boppart; P Scott Carney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-04       Impact factor: 2.129

5.  Nonparaxial vector-field modeling of optical coherence tomography and interferometric synthetic aperture microscopy.

Authors:  Brynmor J Davis; Simon C Schlachter; Daniel L Marks; Tyler S Ralston; Stephen A Boppart; P Scott Carney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-09       Impact factor: 2.129

6.  High-resolution optical coherence tomography over a large depth range with an axicon lens.

Authors:  Zhihua Ding; Hongwu Ren; Yonghua Zhao; J Stuart Nelson; Zhongping Chen
Journal:  Opt Lett       Date:  2002-02-15       Impact factor: 3.776

7.  In vivo ultrahigh-resolution optical coherence tomography.

Authors:  W Drexler; U Morgner; F X Kärtner; C Pitris; S A Boppart; X D Li; E P Ippen; J G Fujimoto
Journal:  Opt Lett       Date:  1999-09-01       Impact factor: 3.776

8.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

9.  In vivo endoscopic optical biopsy with optical coherence tomography.

Authors:  G J Tearney; M E Brezinski; B E Bouma; S A Boppart; C Pitris; J F Southern; J G Fujimoto
Journal:  Science       Date:  1997-06-27       Impact factor: 47.728

10.  Interferometric synthetic aperture microscopy.

Authors:  Tyler S Ralston; Daniel L Marks; P Scott Carney; Stephen A Boppart
Journal:  Nat Phys       Date:  2007-02-01       Impact factor: 20.034

View more
  10 in total

1.  Computational adaptive optics for broadband optical interferometric tomography of biological tissue.

Authors:  Steven G Adie; Benedikt W Graf; Adeel Ahmad; P Scott Carney; Stephen A Boppart
Journal:  Proc Natl Acad Sci U S A       Date:  2012-04-26       Impact factor: 11.205

2.  Computed optical interferometric tomography for high-speed volumetric cellular imaging.

Authors:  Yuan-Zhi Liu; Nathan D Shemonski; Steven G Adie; Adeel Ahmad; Andrew J Bower; P Scott Carney; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2014-08-08       Impact factor: 3.732

3.  Computational optical coherence tomography [Invited].

Authors:  Yuan-Zhi Liu; Fredrick A South; Yang Xu; P Scott Carney; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2017-02-16       Impact factor: 3.732

4.  Review of intraoperative optical coherence tomography: technology and applications [Invited].

Authors:  Oscar M Carrasco-Zevallos; Christian Viehland; Brenton Keller; Mark Draelos; Anthony N Kuo; Cynthia A Toth; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

5.  Guide-star-based computational adaptive optics for broadband interferometric tomography.

Authors:  Steven G Adie; Nathan D Shemonski; Benedikt W Graf; Adeel Ahmad; P Scott Carney; Stephen A Boppart
Journal:  Appl Phys Lett       Date:  2012-11-29       Impact factor: 3.791

6.  Multifocal interferometric synthetic aperture microscopy.

Authors:  Yang Xu; Xiong Kai Benjamin Chng; Steven G Adie; Stephen A Boppart; P Scott Carney
Journal:  Opt Express       Date:  2014-06-30       Impact factor: 3.894

7.  Computed Optical Interferometric Imaging: Methods, Achievements, and Challenges.

Authors:  Fredrick A South; Yuan-Zhi Liu; P Scott Carney; Stephen A Boppart
Journal:  IEEE J Sel Top Quantum Electron       Date:  2015-11-02       Impact factor: 4.544

8.  Intraoperative Assessment of Final Margins with a Handheld Optical Imaging Probe During Breast-Conserving Surgery May Reduce the Reoperation Rate: Results of a Multicenter Study.

Authors:  Adam M Zysk; Kai Chen; Edward Gabrielson; Lorraine Tafra; Evelyn A May Gonzalez; Joseph K Canner; Eric B Schneider; Andrew J Cittadine; P Scott Carney; Stephen A Boppart; Kimiko Tsuchiya; Kristen Sawyer; Lisa K Jacobs
Journal:  Ann Surg Oncol       Date:  2015-07-23       Impact factor: 5.344

9.  Comparison of a MEMS-Based Handheld OCT Scanner With a Commercial Desktop OCT System for Retinal Evaluation.

Authors:  Samir I Sayegh; Ryan M Nolan; Woonggyu Jung; Jeehyun Kim; Daniel T McCormick; Eric J Chaney; Charles N Stewart; Stephen A Boppart
Journal:  Transl Vis Sci Technol       Date:  2014-06-25       Impact factor: 3.283

10.  Characterizing the point spread function of retinal OCT devices with a model eye-based phantom.

Authors:  Anant Agrawal; Megan Connors; Alexander Beylin; Chia-Pin Liang; David Barton; Yu Chen; Rebekah A Drezek; T Joshua Pfefer
Journal:  Biomed Opt Express       Date:  2012-04-26       Impact factor: 3.732

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.