Literature DB >> 20479492

Robust FFT-based scale-invariant image registration with image gradients.

Georgios Tzimiropoulos1, Vasileios Argyriou, Stefanos Zafeiriou, Tania Stathaki.   

Abstract

We present a robust FFT-based approach to scale-invariant image registration. Our method relies on FFT-based correlation twice: once in the log-polar Fourier domain to estimate the scaling and rotation and once in the spatial domain to recover the residual translation. Previous methods based on the same principles are not robust. To equip our scheme with robustness and accuracy, we introduce modifications which tailor the method to the nature of images. First, we derive efficient log-polar Fourier representations by replacing image functions with complex gray-level edge maps. We show that this representation both captures the structure of salient image features and circumvents problems related to the low-pass nature of images, interpolation errors, border effects, and aliasing. Second, to recover the unknown parameters, we introduce the normalized gradient correlation. We show that, using image gradients to perform correlation, the errors induced by outliers are mapped to a uniform distribution for which our normalized gradient correlation features robust performance. Exhaustive experimentation with real images showed that, unlike any other Fourier-based correlation techniques, the proposed method was able to estimate translations, arbitrary rotations, and scale factors up to 6.

Year:  2010        PMID: 20479492     DOI: 10.1109/TPAMI.2010.107

Source DB:  PubMed          Journal:  IEEE Trans Pattern Anal Mach Intell        ISSN: 0098-5589            Impact factor:   6.226


  3 in total

1.  Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.

Authors:  Sungheon G Kim; Li Feng; Robert Grimm; Melanie Freed; Kai Tobias Block; Daniel K Sodickson; Linda Moy; Ricardo Otazo
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

2.  A novel technique for prealignment in multimodality medical image registration.

Authors:  Wu Zhou; Lijuan Zhang; Yaoqin Xie; Changhong Liang
Journal:  Biomed Res Int       Date:  2014-05-22       Impact factor: 3.411

3.  Geometric Correction for the Geostationary Ocean Color Imager from a Combination of Shoreline Matching and Frequency Matching.

Authors:  Han-Gyeol Kim; Jong-Hwan Son; Taejung Kim
Journal:  Sensors (Basel)       Date:  2018-10-23       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.