Literature DB >> 20479448

Strength of braided polyblend polyethylene sutures versus braided polyester sutures in Achilles tendon repair: a cadaveric study.

Keith D Cook1, Greg Clark, Eric Lui, Gaurav Vajaria, George F Wallace.   

Abstract

BACKGROUND: Various techniques may be used to repair Achilles tendon ruptures; however, we contend that using the strongest suture with the least amount of suture material is ideal.
METHODS: To compare the strength of 2-0 FiberLoop (Arthrex Inc, Naples, Florida) and #2 Ethibond (Ethicon Inc, Somerville, New Jersey) suture materials in Achilles tendon repairs, 12 Achilles tendons were harvested from cadavers aged 18 to 62 years (median age, 42 years). The tendons were transected and repaired using a modified Krackow suture technique. All of the right limbs were repaired with 2-0 FiberLoop, and the contralateral side was repaired with #2 Ethibond. The specimens were mounted to a materials testing system, and the repairs were pulled to failure in an anatomical direction.
RESULTS: The mean +/- SD yield loads of 2-0 FiberLoop and #2 Ethibond were 233 +/- 48 N and 134 +/- 34 N, respectively (P = .002). The mean +/- SD ultimate load of 2-0 FiberLoop was 282 +/- 58 N, and that of #2 Ethibond was 135 +/- 33 N (P < .001). The cross-sectional area of one pass of 2-0 FiberLoop was calculated to be 0.21 mm(2), and one pass of #2 Ethibond was 0.28 mm(2).
CONCLUSIONS: The smaller-caliber 2-0 FiberLoop was significantly stronger than #2 Ethibond. This study suggests that there is no advantage to using the traditional larger suture material for Achilles tendon repairs; however, further clinical testing is needed to determine the optimal repair technique.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20479448     DOI: 10.7547/1000185

Source DB:  PubMed          Journal:  J Am Podiatr Med Assoc        ISSN: 1930-8264


  3 in total

Review 1.  Initial Achilles tendon repair strength--synthesized biomechanical data from 196 cadaver repairs.

Authors:  Patrick Sadoghi; Claudio Rosso; Victor Valderrabano; Andreas Leithner; Patrick Vavken
Journal:  Int Orthop       Date:  2012-03-31       Impact factor: 3.075

Review 2.  Modified triple Kessler with least risk of elongation among Achilles tendon repair techniques: a systematic review and network meta-analysis of human cadaveric studies.

Authors:  Pedro Diniz; Jácome Pacheco; Ricardo M Fernandes; Hélder Pereira; Frederico Castelo Ferreira; Gino M M J Kerkhoffs
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-06-05       Impact factor: 4.342

3.  Biomechanical Head-to-Head Comparison of 2 Sutures and the Giftbox Versus Bunnell Techniques for Midsubstance Achilles Tendon Ruptures.

Authors:  Rufus O Van Dyke; Sejul A Chaudhary; Gregory Gould; Roman Trimba; Richard T Laughlin
Journal:  Orthop J Sports Med       Date:  2017-05-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.